Note 1: Change oil after first two (2) operating hours and every 50 operating hours
thereafter, more often if operated in extremely dusty or dirty conditions.

Note 2: Check oil after 5 hours of operation.

Note 3: Every 100 hours of operation or once a year.

CUSTOMER RESPONSIBILITIES TABLE

MAINTENANCE TASK

Before

each

use

Every 25

Hours of

Every

Season

Every 50

Hours of

Every

Season

Every 100

Hours of

Every

Season

Check Spark Plug

Prepare unit for storage if it is to remain
idle for more than 30 days.

MAINTENANCE

Check oil level

Change oil

Clean Air Filter Assembly

Prepare Unit for Storage

See Note 2

X

See Note 1

X

X

See Note 3

Clean Fuel Valve Bowl

X

Clean Fuel Filter

X

Clean Fuel Tank Filter

X

Clean Muffler Screen

X

GENERAL RECOMMENDATIONS

The warranty of the generator does not
cover items that have been subjected to
operator abuse or negligence. To
receive full value from the warranty,
operator must maintain the generator as
instructed in this manual.

GENERATOR MAINTENANCE

Your generator should be kept clean and
dry at all times. The generator should
not be stored or operated in
environments that include excessive
moisture, dust or any corrosive vapors. If
these substances are on the generator,
clean with a cloth or soft bristle brush.
Do not use a garden hose or anything
with water pressure to clean the genera-
tor. Water may enter the cooling air slots
and could possibly damage the rotor,
stator and the internal windings of the
gen head.

ENGINE

To Check Oil

1.

Shut down engine and place on a
level surface.

2.

Remove the oil filler cap/dipstick
cover.