beautypg.com

Ryobi EMT0005 User Manual

Measuretech, Emt0005 electronic, Verifying if the unit works

background image

X

sq.

cu.

ft.

m.

EMT0005

ELECTRONIC

MeasureTech™

EMT0005

ELECTRONIC

MeasureTech™

The Ryobi Electronic

MeasureTech™ is intended for

a fast, convenient distance measure, or with a laser
pointer which shows exactly the location where the
measurement will be taken. It features a sleek,
high-impact case.

For damage caused by usage other than intended,
the user is responsible.

VERIFYING IF THE UNIT WORKS

• After battery is installed,press the “READ”

button. If numbers appear on the LCD display,
then the unit is working properly.

983000-284

6-03

FEATURES

• Instant measurement
• Dynamic measurement capability of 50 feet

(15 meters)

• Selective measurement reference: top or bottom

of the case

• Computation of area and volume
• 5 digit LCD for easy read screen
• Built in laser pointer
• Conversion ft-in to metric

MEASUREMENT REFERENCE

• Press “SET” button to select measurement
base: top or bottom of case.
• To change from feet to meters, or vice versa,

press the “set” and “X/=” button simultaneously.

NOTE:

The

MeasureTech™ measurement unit is

defaulted in ft-in.

MEASUREMENT PROCEDURES

• Select the measurement reference.
• Point the unit perpendicular to the target. The

laser will show where the estimator is pointed
and is on only while a reading is being taken.
Caution: Do not stare into Laser beam. Hold
unit with beam above or below eye level.

• Press the “READ” button to take the measure-

ment.

• Hold the “READ” button for continuous

measurement.

Finding square footage/meters and
cubic footage meters

• After taking initial measurement, press the “X/=”

key. Take the second measurement and again
press the “X/=’’ key. LCD display will show
“SQ.M”. Take a third measurement and again
press “X/=” key. LCD display will show “cu.ft”. or
“cu.m”.

HINTS

• Any large obstacle found within + 5

°

for the view-

ing angle of the unit might be regarded as the
target.

• Large, flat, hard surfaces usually give more

accurate results.

• To measure small, irregular or soft objects, place

a piece of cardboard in front of the object.

• Change of measurement base does not affect old
readings.
• The unit cannot measure through glass.

ERROR DISPLAY

The unit will give inaccurate readings if:
• The battery runs out of power
• The distance to be measured is less than 2’

(0.6m) or

• There is another ultrasonic source in the vicinity.
“ERROR” will be displayed if the reflected

ultrasonic pulses are not strong enough.

This may happen when:

-The measuring distance is out of working range.
-The target is not a good ultrasonic reflector

(e.g. thick carpet, irregular wall paper, etc.)

-The unit of the multiplication result is higher than
cube.

INSTALLING THE BATTERY

• Slide back of unit off to replace battery.
• Snap 9-V battery into compartment, terminal side

first, matching (+) and (-) terminals from battery to
case.

• Replace the back by sliding into grooves. Alkaline

battery life is approximately 7000 measurements.

• The battery should be replaced when battery

indicator is on.

PARTS IDENTIFICATION
KEYBOARD

1. SET - Select measurement reference
2. READ - Read distance
3. X / = - Multiply / equal

OTHERS

4. Laser aperture
5. Display
6. Measurement reference - top
7. Measurement reference - bottom
8. Battery compartment ( back )

USE AS INTENDED:

The

MeasureTech™ is intended for a fast,

convenient distance measurement with a laser
pointer which shows exactly where the

measurement is being taken.

CAUTIONS

• Do not expose the unit to direct sunlight, high

temperature, high humidity, excess dust, or

mechanical shock.
• When the unit is not to be used for a long
period, remove the battery to avoid damage

from possible battery leakage.

• It is a household product.
• Not for repair, open only by authorized persons.

OPERATING ENVIRONMENT

• Temperature 32

°

F to 104

°

F (0

°

to 40

°

).

• Still Air
• Hard Surface

Situations

Possible Causes

Solutions

WARRANTY

This product is a consumable item.
Therefore it is warranted against
defective parts and labor only and not
misuse or deterioration of product
through normal wear and tear for a period
of 2 years from date of purchase.

WARNING: To avoid risk of eye injury, do not stare directly into beam. Never point the beam into anyone’s

eyes. Do not permit children to use this device. It is not a toy.

SPECIFICATIONS

• Class II Laser Module 650 mm.
• Measurement Range 2’ to 50’ (0.6 m to

15 m)

• Accuracy: + 0.5% + 1 Digit (*)
• Resolution: 1’ (0.01 m)
• Apeture angle: Approx. + 5 Degrees
• Calculation Range: Length - 999’11”

(999.99 m)
Area - 99999 Sq.ft (999.9 SQ M)
Volume - 99999 Cb. ft (9999.9 CB M)

• Power Consumption: Approx. 0.4 W
Average
• Display: 5 Digits Liquid Crystal Display
• Battery: 9 Volt
• Size: 4.84”X2.36”X1.54”:
(123 mm X 60 mm X 39 mm)
• Weight (Without Battery):
Approx. 3.14 oz(88g)

(*)For measuring long distance from 40 ft

to 50 ft (2m to 15m), the relative humidity
should be 50% or above and target size
should be at least 10 ft. by 10 ft (3m by
3m).

DISPLAY

SQUARE

CUBIC

MULTIPLY

FEET

METER

REFERENCE
(TOP)

REFERENCE
(BOTTOM)

LOW
BATTERY
INDICATOR

RYOBI TECHNOLOGIES INC.

1428 Pearman Dairy Road

Anderson, SC 29625

www.ryobitools.com

1-800-525-2579

Inaccurate readings
of distance

LCD displays “Error”

• Battery runs out of power
• Measured distance is < 2’ or > 50’

(< 0.6m or > 15m).

• Another ultrasonic source is nearby

Measured distance is < 2’ or > 50’

(< 0.6m or > 15m).

The target is not a good ultrasonic

reflector. (e.g. thick carpet, irregular
wallpaper, etc.).

The unit points to the target ob-

liquely.

• Computation is out of the specified

range.

• Replace new battery
• Make sure measured distance is within range
• Remove the ultrasonic source and try again.

• Make sure mearured distance is within range.
• Place a piece of cardboard in front of target.
• Make sure computation is within range.

CAUTION

Avoid direct exposure to the

beam. Read instructions

in manual.

Class II Laser Product

Max. Power Output < 1mw Wavelength: 640-670 nm

Complies with CFR 21 parts 1040.10 and 1040.11

SET

x / =

READ

ft

2' 0"

4

6

1

5

2

3

7

8

SET

x / =

READ

2 ft. min.

ft

2' 0"