S e l e c t i n g f u n c t i o n s

AIR CONDITIONING FUNCTIONS

To turn the unit on in air conditioning mode,

proceed as follows:

1. Press the ON/OFF button

(the signal

light

will come on).

2. Rotate the function selector

dial anti-

clockwise:

Place the function selector in the HIGH
pos. to operate the unit in air conditioning
mode at maximum fan speed, after 3
minutes the signal light

will come on ).

Place the function selector in the LOW
pos. to operate the unit in air condtioning
mode at minimum fan speed (the signal
light

will come on, and then, after 3

minutes the signal light

will come on ).

3. Now set the required temperature by rota-

ting the room thermostat dial

.

Note

The temperature is not expressed in degrees.
We recommend that you turn the thermostat
dial to the maximum position. When the desi-
red room temperature has been reached,
slowly turn the thermostat in a clockwise
direction until it arrives at the position where a
click can be heard. The signal lights

(or

) will turn off.

The temperature selected in this way will
automatically be regulated and maintained,
and save energy. When regulating the ther-
mostat, the air conditioning function is tem-
porarily interrupted and the unit continues to
operate in fan only mode. In this way, the
appliance keeps the air temperature within
the room even.

Delay on Start Up

1. A special safety device will delay the start

of air conditionig by approximately 3 to 5
minutes when switching between func-
tions or on initial start up.

2. You may also experience a slight delay

between changing from one function to
another.

16

15

20

16

21

15

19

10

11

VENTILATION/FILTRATION

Rotate the function selector

clockwise.

Press the ON/OFF

button

(the signal

light

will come on).

Place the function selector on the “FreshZo-
ne
” position and choose the desired fan
speed (min/max). The signal light

or

will come on).

17

10

11

19

COOL JET

The cool jet mode was conceived to provide
the appliance with a greater cooling poten-
tial. This is particularly useful when you want to
bring the temperature of a very warm room
quickly down to a more comfortable level. In
this case:
Make sure that the tank is full of water (see
page 8);
Make sure that the function selector switch

is in the HIGH position.

Press the Cool jet button

.

After reaching the desired temperature, you
can release the Cool jet button and reposi-
tion the selector switch to the LOW pos.
Doing so will make the operation quiter.

22

19

18

PROBLEM WARNING LIGHT

The lighted pilot light

indicates that

the safety device of the pressure switch has
switched on. In this case the appliance is
deactivated. To restore the proper functio-
ning of the appliance, eliminate the possible
causes of the problem and press the restore
button

.

The causes may be:

1) The exhaust hose forms a siphon in which

condensation water has accumulated: in
this case, it is necessary to drain the accu-
mulated out of the machine, outwards
(never towards the air conditioner) and
eliminate the siphon on the hose.

2) The exhaust hose is obstructed: eliminate

the obstacles which obstruct the expulsion
of the air to the outside.

If, after having repositioned the drainage tube,
the machine still does not start up, the problem
might be more complicated (ex.: obstructed
ventilation fan) and could require the assistan-
ce of the Authorised Service Centre.

6