beautypg.com

Operating/maintenance tips, Questions and answers/troubleshooting – Kirby Sentria User Manual

Page 45

background image

44

Q

WHAT IS A DOUBLE-INSULATED MACHINE? (Servicing of double-insulated appliances)

A

In a double-insulated appliance, two systems of insulation are provided instead of grounding. No

grounding means is necessary on a double-insulated appliance, nor should a means for grounding be added

to the appliance. A double-insulated appliance is marked with the words “DOUBLE-INSULATED”

(U.S.A. and Canada). The symbol ( square within a square) may also be marked on the appliance.
Servicing a double-insulated appliance requires extreme care and knowledge of the system and

should be done only by qualified service personnel.
Replacement parts for this double-insulated Sentria® model must be genuine Kirby® parts

for maintenance of safety and protection of warranty.

Q

WHAT SHOULD I DO IF THE MOTOR DOES NOT RUN WHEN I TURN

THE

Sentria

SYSTEM ON?

A

Many service calls are unnecessary. Checking a few simple things can save a lot of cost, time and

trouble. Whenever your Sentria system does not perform properly, make these checks first before

calling authorized service personnel.
IF THE MOTOR DOES NOT RUN WHEN THE MOTOR ON-OFF SWITCH IS PUSHED:
1. Make sure the Power Cord is plugged into an outlet and that the outlet has power.

(Check for a blown fuse, tripped circuit breaker or power company trouble.)
2. Make sure the cord plug is fully inserted into the unit.
3. Look for breaks in the Power Cord insulation. If the cord is damaged, get a new one.

DO NOT ATTEMPT TO REPAIR IT. Use only a genuine Kirby® Power Cord.

Do not use standard extension cords.
4. Make sure that an attachment or accessory is properly mounted on the front of the Power Plant.

The unit will not run without the Power Nozzle

25

, Hose Coupling, Air Intake Guard or Accessory

Brush Nozzle in place.

5. The unit will not operate without either a Filtration Bag Assembly/ Mini Em-Tor® collector

6

,

Attachment Hose or Carpet Shampoo Tank properly installed on the Air Exhaust Port

19

.

6. The Filtration Bag Assembly/Mini Em-Tor collector, Attachment Hose or Carpet Shampoo Tank

must “click” firmly into place for the unit to operate. If the fitting is too tight and you have difficulty

installing the above, apply a small drop of water to the gasket to reduce friction and ease installation.

Q

WHAT SHOULD I DO IF THE

Sentria

SYSTEM DOES NOT PICK UP LINT

OR DIRT ON THE CARPET?

A

l. Check to see if the Brush Roll is turning, when the Sentria system is running.

2. If the Brush Roll is not turning freely, the belt is slipping, broken or not on the Motor Shaft

23

.

3. If the belt is not on the Motor Shaft

23

, remove the nozzle and follow the instructions on page 16.

See page 42 for bristle extension.
4. If the belt is in good condition and the brush is running, check for bristle wear and replace

Brush Roll, if necessary.
To check for wear, turn the Power Nozzle

25

over and place a ruler against the metal Rug Plate. If the

bristles are below or just touching the ruler, the Brush Roll should be adjusted. See page 42 for details.
5. Make sure that the nozzle height is adjusted to place the brush in contact with the carpet.

Use the Toe-Touch Control to adjust as appropriate. See page 7.
6. Check the bag to see if it is full.
7. Check the fill tube for clogging.

Operating/Maintenance Tips