Operating mode switches, Output wiring, Quick start guide – Wharfedale Pro WX-12 User Manual
Page 6
5
The HPF / LPF / Fullrange Mode Switches allow your WX
amplifier to drive a bi-amplified system without an additional
active crossover network. LPF is used to drive subwoofers, HPF
to drive a Mid/Hi enclosure and Fullrange is used to drive a Mid/
Hi enclosure without a subwoofer.
OPERATING MODE SWITCHES
OPERATING MODE
Built-in filter
Frequency response of the amplifier
Top
HPF
6dB/oct 00Hz High Pass Filter
00Hz-20KHz
Middle
FULL RANGE
Bypassed
20Hz-20KHz
Bottom
LPF
6dB/oct 00Hz Low Pass Filter
20Hz-00Hz
The WX Series employ Speakon output connectors. Ensure
that only heavy gauge two conductor speaker cables with
professionally wired Speakon connectors are used for
connection from amplifier to loudspeaker.
OUTPUT WIRING
1. Make sure that the power switch is set at the OFF position while making connections to and from the power amplifier.
2. Connect all devices in the signal path and ensure that each connection is secure.
3. Set all level and gain controls to their minimum.
4. After powering up all other devices first, turn the power switch on the amplifier to the ‘ON’ position and verify that the
POWER LED is illuminated.
5. Turn the amplifier volume control up to the “7” setting. (This setting can be adjusted higher or lower, as needed,
after set-up). With source signal present start to set each gain stage in your signal path, starting at the beginning of
the chain. It is best practice to make overall volume changes with the master fader of your mixing console once the
amplifier input trim has been calibrated.
6. When powering down, make sure that the power amplifiers are switched off first.
QUICK START GUIDE