6

7

WIRING

All electrical wiring should be carried out by a registered electrical

contractor and must conform to the latest IEE wiring regulations

Do not switch the power on until the unit has been filled with

water and all wiring has been earthed, see Fig. 4 and 5.

FITTING IMMERSION HEATERS

These are supplied as standard

An ’O’ ring is supplied as the seal and must be fitted against

the flange of the element. Take care not to cross thread and

DO NOT USE any other type of seal.

Fig.5

L

N

E

As our heating element is Incoloy 825 and is fitted with a cut-

out and thermostat for safety, a non-standard 1

3/4

" boss is fitted

to the unit. Replacements can only be obtained from your

authorised Dimplex Service Agent.

All our heating elements have a built in manual reset cut-out.

This will operate if the immersion heater thermostat fails.

WARNING

: Ensure that the immersion heater thermostat is set

at 60 degrees Celsius.

FITTING THE THERMAL CUT-OUT &
PRIMARY CONNECTIONS

The motorised valve supplied and the thermal cut-out (Hi

limit stat) must be fitted to the primary flow. Use

compression fittings only.

Operation of the cut-out and motorised valve

To comply with BBA regulations and to prevent the

temperature reaching 100 degrees Celsius the thermal

cut-out supplied must be fitted.

The thermal cut-out is wired in series to the cylinder

thermostat. When the thermal cut-out senses an abnormal

rise in temperature in the primary flow the electrical supply

to the motorised valve will be cut, and the valve will be in

the closed position thus cutting of the primary water from

the boiler to the indirect coil in the cylinder. If this occurs it

must be reset manually. If the thermal cut-out operates

check the cylinder stat and / or boiler stat.

SECONDARY CIRCULATION
CONNECTION DIAGRAM

Fig.3

2 PORT VALVE + 3 PORT MID POSITION
VALVE (Y-PLAN) SYSTEM
GUIDANCE LAYOUT ONLY

1
2
3

4
5
6
7
8
9

10

Br BI G O GY

1 3 2

Br BI G O

L N E

HTG

ON

DHW

ON

PROGRAMMER

TWIN

THERMOSTAT

MOTOR ON/OFF

VALVE

PUMP

BOILER

2 PORT MID

POSITION VALVE

ROOM

THERMOSTAT

2

1

C

2

1

C

E

N

L

E

N

L

E N L

GY

GY

GY

2 * 2 PORT (S-PLAN) VALVE SYSTEM
GUIDANCE LAYOUT ONLY

Fig.4

Dimp-15278-SCx_Instructions 31/3/06 9:32 am Page 7