Tube Tech LCA 2A Stereo Compressor User Manual
Page 7

LYDKRAFT Aps
Ved Damhussøen 38, DK 2720 Vanløse
Denmark
7
SERVICE HINTS:
SYMPTOM
CAUSE
REMEDY
Noise
Noisy VCA tube (V1,V101)
Replace and adjust
Noise
Unbalance in VCA tube
Adjust balance
Noise
Control amp IC 4 (IC 104)
Replace. Check gain
reduction and readjust
Hum
+12V, +110V ,+15V PSU
Repair
Overshoot when
compressing
Unbalance in VCA tube
Adjust balance
Oscillations with no signal and
max ratio and low threshold
Unbalance in VCA tube
Adjust balance
(replace tube)