3
ATTACK/RELEASE SELECT:
This switch selects how the compressor reacts to an increase
(attack) or decrease (release) of the input signal.
There are two settings of the switch:
1.
Manual.
Attack time: from 0.3 mS to 10 mS
Release time: from 0.07 sec to 2 sec
2.
Preset.
Attack
Release
pos 1.
1,5 mS
0,25 S
pos 2.
1,5 mS
0,8 S
pos 3.
3 mS
2,2 S
pos 4.
6 mS
5,0 S
pos 5.
3 mS
0,5/4 S
pos 6.
1,5 mS
0,5/4/20 S
The release time in position 5 and 6 is program dependent, that is:
pos 5, 6
for short peaks:
0,5 S
pos 5, 6
for long peaks:
4 S
pos 6
for continuously high levels:
20 S
LIMITER:
ON/OFF
This switch defeats the limiter when in the off position
THRESHOLD:
The threshold is related to the output level and is continuously
variable from off to 0dBU.
Ratio:
20:1
Attack:
0,6 mS
Release:
0,5 S
(940530)