beautypg.com

Tube Tech CL 1B Opto Compressor User Manual

Page 6

background image

LYDKRAFT ApS

Mose Allé 20, DK 2610 Rødovre

Denmark

6

ADJUSTMENT PROCEDURE:

CAUTION:

Before making any adjustment let the unit heat-up at least 15 min.
Observe that the offset-voltage measured at the side chain jack socket, when the
THRESHOLD is off, is not greater than +/- 15 mV DC in both position "fixed" and
"manual".
(tip is bus 1 and ring is bus 2).

If the voltage exceeds this value, replace either IC1 or IC2.

THE GRE SHALL BE MARKED BETWEEN 1.225-1.285

ADJUSTMENT OF BASIC GAIN:

1)

Apply a signal of 1 kHz, -30,0 dBU into the input of the compressor.

2)

Turn the GAIN-control fully clockwise.

3)

Set the RATIO-control at 2:1

4)

Adjust the pre-set GAIN (located on amp/psu PCB) to an output-reading of 0,0 dBU.

ADJUSTMENT OF COMPRESSION TRACKING:

1)

Turn the THRESHOLD-control fully counter-clockwise.

2)

Set the RATIO-control at 2:1.

3)

Set the BUS-select-switch at 1.

4)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.

5)

Adjust the GAIN-control to an output-reading of 0,0 dBU.

6)

Apply a DC-voltage of +250,0 mV into the side chain jack socket (tip) and observe that

the output level has dropped to -10,0 dB.

7)

If this is not the case, adjust the level with P 2 (P 1)*, to obtain a drop of exactly -10,0 dB.

*

The trimpots in parenthesis refers to PCB 870316-0,1,2

(

980810)