BOOST:

The BOOST control is continuously variable and is of the bell type.
The gain is depending of the setting of the bandwidth control.
When the bandwidth is in the sharp position the gain is from 0 dB to +18dB.
When the bandwidth is in the broad position the gain is from 0 dB to +10dB.

HIGH
FREQUENCY: The HIGH FREQUENCY switch determines at which frequency the

maximum boosting is obtained. There is a choice of 10 frequencies:
1, 1.5, 2, 3, 4, 5, 8, 10, 12 and 16kHz.

ATTENUATE SECTION:

ATTEN:

The ATTENuate control is continuously variable from 0 dB to -18 dB.
It is of the shelving type.

ATTEN SEL:

The ATTEN SELect switch determines at which frequency the maximum
attenuation is obtained. There is a choice of 3 frequencies:
5, 10 and 20 kHz.

IN/OUT:

This lever switch switches the filter in and out of the signal path.
The amplifier remains in the circuit.

(030507)