Input valves can be replaced individually but “distortion”
valves should be replaced in matched pairs if you use the
unit for stereo. (otherwise it can be quite fun to have
different sounds from each side – some of our old
customers prefer it!)
Valve complement: (equivalents in brackets, nearest 1
st
)
Input
2 x 5654 (M8100, EF95, 6AK5)
Distortion
2 x 5725 (6AS6)
Output -
1 x 13D5 (ECC82, 12AU7)
5.2 Operating voltage / Fuse
The Culture Vulture Mastering Plus is switch selectable to
operate from either 230V or 115V 50/60Hz AC mains
supply.
NOTE: Mains fuses may be replaced in accordance with
the following table:
Operating Voltage
Fuse Rating
115V
T500mA 20mm type
230V
T250mA 20mm type