Thermionic Culture THE CULTURE VULTURE Stereo Valve enhancer User Manual
Page 9
© Thermionic Culture Ltd, October 2005
8
5
Servicing & Maintenance
5.1 Valves
All valves are selected to ensure that the unit gives
optimum and consistent performance across both
channels.
Although Thermionic Culture Ltd. guarantees the valves for
twelve months, they can last for up to twenty years.
Spares can be obtained from Thermionic Culture Ltd.
Valve complement:
Input -
2 x EF86;
Distortion - 2 x 6AS6;
Output -
5963 (12AU7 / ECC82 near equivalent)
5.2 Operating voltage / Fuse
The Culture Vulture is switch selectable to operate from
either 230V or 115V 50/60Hz AC mains supply.
NOTE: Mains fuses may be replaced in accordance with
the following table:
Operating Voltage
Fuse Rating
115V
T500mA 20mm type
230V
T250mA 20mm type