Specifications, General installation instructions – TFC Group Towerchron QM2 User Manual
Page 5
GB
EN
5
Specifications
Installation
double insulated
Rating
5 amps (2 amps) at 240
volts 50 hertz
Fitting
surface mounted or to a
single gang plaster depth
socket outlet
Dimensions
156 x 85 x 42
Maximum ambient
temperature
50° centigrade
Type 1 action
Micro disconnection
Type 1B
Pollution protection
Normal pollution situation
General installation instructions
The TOWERCHRON QM1 and QM2 are both
double insulated so earth protection is not
required� However in the backplate a terminal for
earth continuity is provided which should be used
if earth conductors are present in your cable�
Make sure that the earth conductors are sleeved
to prevent accidental contact with live parts�
N
Fixing
Holes
Cable
Knockout
Fixing
Screw
Earth
Terminal
Terminal
Block
Backplate
L
1
2
3
4