TFC Group ECO ET3 User Manual

Page 2

background image

F, Jumper Locations:

D, Setting Temperature:
- Adjust the temperature to your chosen set-point using the or

buttons.

- Ambient room temperature display will resume after 8 seconds and the

icon will disappear.


E, Jumper Selection:

Delay / No Delay Jumper:

Heater

Cooler

No Delay

10sec

4mins

Delay

4mins

4mins

Choose the delay option if compressor heat is connected.

Heater/Cooler Jumper:

Select the heater option (default) when a heater is connected to the
receiver. Select the Cooler option when using the ET3 for a cooling

application, fan cooling etc. Press “reset” (RST) after modifying jumper
selections.

G, Comms Address Setting:

Inside the transmitter and receiver there is a bank of 9 dip switches for

setting a unique address (pairing). The receiver will ignore
communications from transmitters set to a different address. To access

the dip switches it is necessary to open the thermostat and remove the
front cover from the receiver by removing the two crosshead screws on

the rear cover.

7

8

9 10

Transmitter dip switches

Receiver
dip switches

The dip switches on both units must
be set identically to communicate.

H, Specification:

1, Temperature Measurement:

0

0

C - 4

0

C

(0.1

0

C/step)

2,

Accuracy:

± 0.5

0

C

3, Temperature Control Range:

5

0

C - 35

0

C

(0.5

0

C/step)

4,

Terminals:

2.5mm

2

Cable

5, Electronic Control:

Type 2.B action

6, Transmitter Batteries:

2 x 1.5V AAA

Alkaline batteries

7, Receiver Input Voltage:

240V AC

8, Receiver Output Voltage:

24..240V AC

50/60Hz

10(3)A

Max

9, Operating Temperature:

0

0

C - 50

0

C

10, Storage Temperature:

0

0

C - 60

0

C

11, Sensing Element:

NTC Thermistor


11 12

I, Terminal Connecting Block Label:

1

2

3

Default jumper setting:
No Delay & Heating