Cooling performance with evaporator coils, 2ac13 split system air conditioner – Ducane (HVAC) 2AC13 User Manual
Page 3
![background image](/manuals/74263/3/background.png)
2AC13 Split System Air Conditioner
13
** = B, L, BC, LC
* = B, L
Cooling Performance with Evaporator Coils
Outdoor
Model
Indoor Model
SEER
EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor
Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
Suction
Liquid
Suction
Liquid
E(C,M,U)1P18N(A,B)
E(C,M,U)2T18N(A,B)
13.00 11.00
17,000
12,200
550
3/4
3/8
3/4 3/8
3/4
3/8
.053
A2TXV01
E(C,M,U)1P19NA
E(C,M,U)2T19NA
13.00 11.50
17,000
12,200
550
3/4
3/8
3/4 3/8
3/4
3/8
.053
A2TXV01
E(C,H,M,U)1P23N(A,B) E(C,H,M,U)2T23N(A,B) 13.00 11.50
17,000
12,200
550
3/4
3/8
3/4 3/8
3/4
3/8
.053
A2TXV01
E(C,M,U)1P24N(A,B)
E(C,M,U)2T24N(A,B)
13.00 11.50
17,000
12,200
550
3/4
3/8
3/4 3/8
3/4
3/8
.053
A2TXV01
E(C,M,U)1P19NA
E(C,M,U)2T19NA
13.00 11.00
22,800
17,100
750
3/4
3/8
3/4 3/8
3/4
3/8
.062
A2TXV01
E(C,H,M,U)1P23N(A,B)
E(C,H,M,U)2T23N(A,B)
13.00 11.00
23,200
17,400
750
3/4
3/8
3/4 3/8
3/4
3/8
.062
A2TXV01
E(C,M,U)1P24N(A,B)
E(C,M,U)2T24N(A,B)
13.00 11.00
23,000
17,300
750
3/4
3/8
3/4 3/8
3/4
3/8
.062
A2TXV01
E(C,H,M,U)1P29NA
E(C,H,M,U)2T29NA
13.00 11.50
23,000
17,300
750
3/4
3/8
3/4 3/8
3/4
3/8
.062
A2TXV01
E(C,H,M,U)1P23N(A,B)
E(C,H,M,U)2T23N(A,B)
13.00 11.00
27,800
20,900
900
3/4
3/8
3/4 3/8
3/4
3/8
.070
A2TXV01
E(C,H,M,U)1P29NA
E(C,H,M,U)2T29NA
13.00 11.00
28,600
21,500
900
3/4
3/8
3/4 3/8
3/4
3/8
.070
A2TXV01
E(C,M,U)1P30N(A,B,C)
E(C,M,U)2T30N(A,B,C)
13.00 11.00
28,200
21,200
900
3/4
3/8
3/4 3/8
3/4
3/8
.070
A2TXV01
E(C,H,M,U)1P36N(A,B,C)
E(C,H,M,U)2T36N(A,B,C)
13.00 11.00
29,000
21,800
900
3/4
3/8
3/4 3/8
3/4
3/8
.070
A2TXV01
E(C,H,M,U)1P29NA
E(C,H,M,U)2T29NA
13.00 10.50
34,600
26,600
1060 3/4
3/8
3/4 3/8
3/4
3/8
.076
A2TXV01
E(C,H,M,U)1P36N(A,B,C)
E(C,H,M,U)2T36N(A,B,C)
13.00 11.00
34,600
26,600
1060 3/4
3/8
3/4 3/8
3/4
3/8
.076
A2TXV01
E(C,H,M,U)1P43NB
E(C,H,M,U)2T43NBC
13.00 11.00
35,200
27,100
1060 3/4
3/8
7/8 3/8
7/8
3/8
.076
A2TXV01
E(C,H,M,U)1P43NB
E(C,H,M,U)2T43NB
13.00 11.50
40,000
28,000
1250 7/8
3/8
7/8 3/8
7/8
3/8
.080
A2TXV02
E(C,M,U)1P48N(B,C)
E(C,M,U)2T48N(B,C)
13.00 11.00
39,000
27,200
1250 7/8
3/8
7/8 3/8
7/8
3/8
.080
A2TXV02
E(C,H,U)1P49NC
E(C,H,U)2T49NC
13.00 11.00
40,000
28.000
1250 7/8
3/8
7/8 3/8
7/8
3/8
.080
A2TXV02
E(C,H,M,U)1P43NB
E(C,H,M,U)2T43NB
13.00 11.50
45,000
32,000
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,M,U)1P48N(B,C)
E(C,M,U)2T48N(B,C)
13.00 12.00
45,000
32,000
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,H,U)1P49NC
E(C,H,U)2T49NC
13.00 11.50
46,000
32,600
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,M,U)1P50NC
E(C,M,U)2T50NC
13.00 11.50
45,000
32,000
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,U)1P60ND
E(C,U)2T60ND
13.00 11.50
45,000
32,000
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,H,U)1P62NC
E(C,H,U)2T62NC
13.00 12.00
45,500
32,300
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,H,U)1P62ND
E(C,H,U)2T62ND
13.00 12.00
45,500
32,300
1600 7/8
3/8
7/8 3/8
7/8
3/8
.088
A2TXV02
E(C,H,U)1P49NC
E(C,H,U)2T49NC
13.00 11.00
53,000
38,600
1800 7/8
3/8
7/8 3/8 1-1/8 3/8
.098
A2TXV02
EH1P49ND
---
13.00 11.00
53,000
38,600
1800 7/8
3/8
7/8 3/8 1-1/8 3/8
.098
A2TXV02
E(C,H,U)1P62NC
E(C,H,U)2T62NC
13.00 11.50
54,000
39,400
1800 7/8
3/8
7/8 3/8 1-1/8 3/8
.098
A2TXV02
E(C,H,U)1P62ND
E(C,H,U)2T62ND
13.00 11.00
53,000
38,600
1800 7/8
3/8
7/8 3/8 1-1/8 3/8
.098
A2TXV02
2AC13**18P
2AC13**24P
2AC13**30P
2AC13**36P
2AC13*42P
2AC13*48P
2AC13*60P
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.