Test Products International 755 User Manual
Page 2

Contents
•
Specifications
•
Product Features
•
Replacement parts and accessories
•
General Description
•
Operating Instructions
•
Battery Replacement
•
Sensor Replacement
•
Warranty
Specifications
Power Supply:
2 "C" Alkaline Batteries
Sensor:
Conductive Polymer
Ionization (CPI)
Sensitivity:
Selectable to 0.1 oz/yr
134a
Warm up:
Approx 2 seconds
Response time:
Instantaneous
Duty Cycle:
Continuous
Battery Life:
Approx. 30 hrs.
Size:
3.0" x 9.5" x 2.28"
(77 x 240 x 58) mm
Weight:
1.1 lbs (500g)
Probe Length:
16"
Accessories
Standard Accessories:
Sensor:
A721
Instruction Manual:
755 Instruction Manual
Soft Case w/Strap
A755
Optional Accessories:
Earphone
A710
Test vial
A713
General Description
The TPI 755 is a state-of-the-art refrigerant leak
detector capable of detecting al halogen based
gases. The internal diaphragm pump and unique
sensor design provide fast and reliable gas sens-
ing. Selectable sensitivity combined with audible
and visual leak indicators will allow any service
professional to pinpoint those tough to find leaks
even in contaminated environments.
Operating Instructions:
1. Turn the unit on in an uncontaminated environ-
ment pressing the ON/OFF button. Both the
pump and the tick will start.
2. All LED's will illuminate YELLOW indicating auto-