The SENSIT® HXG-2 instrument is an ad-
vanced state-of-the-art leak detector capable
of detecting many combustible, noncombus-
tible and toxic gases.
The SENSIT® HXG-2 solid-state sensor is
sensitive to most combustible and/or toxic
gases. A partial list of these gases is:
Acetone, Alcohol, Ammonia, Steam, Carbon
Monoxide*, Butane, Gasoline, Jet Fuel, Hy-
drogen Sulfide, Smoke, Industrial Solvents,
Methane, Lacquer Thinners, Naphtha, Pro-
pane, Natural Gas.
3
GENERAL DESCRIPTION
This instrument cannot be used for finding
low level carbon monoxide leaks in furnaces
or in the home. Order a Heat Exchanger Test
Kit accessory for testing furnace heat
exchangers.
WARNING
Power Supply: Three “C” size alkaline
batteries.
Sensitivity:
10 ppm methane
Sensor:
Solid State
Alarm:
Visual and audio at
approximately 10% of L.E.L.
with an absolute maximum
of 40% of L.E.L. for methane.
Can be calibrated for other
concentrations or gases.
Warm-up:
Approximately 1 minute
Response Time: < 2 seconds (to 40% L.E.L.)
Recovery Time: < 4 seconds (to 40% L.E.L.)
Duty Cycle:
Intermittent
Battery Life:
Approximately 30 hours.
Dimensions:
3.5” x 10” x 1.6”
Weight:
1.3 lbs.
Probe Length: 16”
Approvals:
UL913 Intrinsically safe
OPERATION ENVIRONMENT
Temperature: 0-120° F
Humidity:
10%-90% R.H.
SPECIFICATIONS
8
* Not to be used to quantify the amount of
CO present.
ACCESSORIES
S0157-1
Calibration Kit (small)
C0130-0.5
Replacement Cal. Cylinder
21 liter 0.5% Methane/Air