beautypg.com

General specifications, Measuring ac/dc voltage, Specifications – Test Products International 100 User Manual

Page 9

background image

5

4

Function

Range

Resolution

Accuracy

DCV

1.5V- 4V

0.001V

40.00V

0.01V

±(0.5% + 4)

400.0V

0.1V

600V

0.1V

±(0.8% + 4)

ACV

1.7V-4V

0.001V

40.00V

0.01V

±(0.8% + 4)

400.0V

0.1V

600V

1V

±(1.2% + 4)

OHM

400.0

0.1

4.000k

0.001k

40.00k

0.01k

±(0.8% + 4)

400.0k

0.1k

4.000M

0.001M

40.00M

0.01M

±(2.0% + 4)

GENERAL SPECIFICATIONS

Power Supply

2 Each 1.5 Volt “AA” Batteries

Battery Life

560 hrs. Alkaline

Size (H x L x W)

45mm x 78mm x 153mm
(1.8” x 3.1” x 6.0”)

Weight

340g (12 oz)

MEASURING AC/DC VOLTAGE

Make sure that the ground and positive leads
are plugged into the proper receptacle for cor-

responding function positions.

Do not attempt to make a
voltage measurement of
more than 500V or of a
voltage that is unknown.

Measurement Procedure:

1. Disconnect power to circuit to be

measured.

2. Plug black test lead into the COM input jack.
3. Plug the red test lead into the V/

W input

jack.

4. Set the rotary switch to the “ON” position.
5. Connect test leads to circuit to be mea-

sured.

6. Reconnect power to circuit to be mea-

sured.

7. Read the voltage on the TPI 100.

Note: For Auto mode to operate
properly, DC voltage must be between
+0.7 and 600V. AC voltage must be
between 3 and 500V.

SPECIFICATIONS