Installation – Sonodyne AMC+250P User Manual
Page 7
![background image](/manuals/741889/7/background.png)
100V Line
70V Line
4 ohm voice-coil
P
P
P
P
P
P
(Per Channel)
(Per Channel)
OUTPUT
DISTANCE
WIRE SIZE
AMC+120P / AMC+1202P
AMC+250P
100V
Up to 50m
AWG24(0.2mm2)
AWG22(0.35mm2)
50m–200m
AWG18(0.75mm2)
AWG16(1.5mm2)
Over 200m
AWG16(1.5mm2)
AWG13(2.5mm2)
70V
Up to 50m
AWG22(0.35mm2)
AWG18(0.75mm2)
50m–200m
AWG16(1.5mm2)
AWG13(2.5mm2)
Over 200m
AWG13(2.5mm2)
AWG10(6.0mm2)
4 ohm
Up to 10m
AWG18(0.75mm2)
AWG18(0.75mm2)
10m–30m
AWG13(2.5mm2)
AWG13(2.5mm2)
Over 30m
Not Recommended
Not Recommended
NOTE: Only connect one output – either Distributed Line or Low Impedance.
Line Output
The LINE output XLR can be used to connect up to 6 booster amplifiers. Balanced wiring
(shielded pair cable) is recommended.
NOTE: When wiring the LINE output as unbalanced, pin 2 should be wired as hot and pin 1
should be wired as ground/shield. Do not wire pin 3.
Input Connections
For wiring balanced in, pin 2 is hot.
Balanced input wiring (shielded pair cable)
is recommended. Unbalanced RCA wiring
should be keep as short as possible.
Direct Output
The output terminal strip accepts wire sizes from 16-22AWG (1.5mm2 –
0.35mm2) or spade lugs. The following table should be used as a guideline
for cable sizes. Regulations in your area may require different gauged wire
and should be checked before using.
PAGE 7
AMC
+
SERIES INSTALLATION AND OPERATION MANUAL
INSTALLATION