Sanuvox R+ User Manual
R+ installation manual, Warning, Please save for your records
Operation
1.
Once installed, the Sanuvox R+ should preferably be plugged into a conditioned dedicated 110V outlet. If one is not available, an
extension cord may be used. For 220V applications, the Sanuvox R+ plug may be cut and hardwired to a dedicated 220V source.
IMPORTANT: When the Sanuvox R+ is turned on, The <
through a warm-up not lasting more than 45 seconds, after which time the unit will become operational and the <
begin to blink. THE UNIT WILL NOT FUNCTION UNTIL THE WARM-UP IS COMPLETE.
2.
To turn the Sanuvox R+ 'ON', press the toggle switch on the center of the front cover to the 'ON' position. The <
appear on the LCD display not lasting more than 45 seconds (warm up). After the warm-up, the purifier will be in "Stand-By Mode" (< By>> will begin to blink). The purifier will remain in Stand-By Mode until the purifier senses air-flow. 3. Upon sensing air-flow the purifier will automatically switch to "Air Purification Mode" The < with useful user information. R+ INSTALLATION MANUAL PLEASE SAVE FOR YOUR RECORDS Serial Number# Date Installed: Installed By: Installers Contact info.: SANUVOX TECHNOLOGIES INC. © 2011 Follow all safety codes. Wear safety glasses and work gloves. 1-888-SANUVOX www.sanuvox.com Before installing or performing maintenance or service on the purifier, turn off main power switch to unit. Electrical shock can cause injury or death. There may be more than one disconnect switch. Never expose eyes or skin to ultraviolet light from any source. The Purifier MUST be DISCONNECTED or service. Personal injury may result. Do not touch Lamp glass without gloves. Reduced performance of Lamp may result. Clean Lamp after handling. Use only specified replacement Lamps with you Purifier. Use of an incorrect Lamp can result in damage to the Purifier and/or Lamp. WARNING WARNING WARNING The UV Lamp contains a small quantity of mercury. If a Lamp breaks, clean and dispose of with care. WARNING WARNING UNDERSTANDING THE LCD DISPLAY Troubleshooting the UV Lamp UV LAMP RESET BUTTON (To be used to reset “Days Left” after UV Lamp change-out) Disconnect the socket from the Lamp. Placing the probe of the ohmmeter to one of the four pins on the end of the Lamp, touch the other probe of the ohmmeter to each of the other pins To the right of the LCD screen is a small hole which houses the RESET BUTTON. To RESET the “Days Left” back to 1096, insert a small object Solid for up to 45 seconds February 2011
from power source before performing maintenance
To check to make sure the UV Lamp has in fact failed:
until you find the matching pin. The ohmmeter will read approximately 3 ohms (almost a short). This indicates that the filament is good. Check the
other two pins. If both sets of filaments test OK, the Lamp is functioning. If one or both sets of filaments read an open circuit (infinity) on resistance,
the Lamp must be replaced.
similar to a paper clip into the hole holding down the button for 3 seconds.