beautypg.com

DeLonghi WIR1 User Manual

Page 3

background image

1.This appliance is only for use with the type

of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.

2.Do not place propane/LP supply tank(s)

inside any structure. Place propane/LP sup-
ply tank(s) outdoors.

3.This heater shall not be installed in a bed-

room or bathroom.

4. If you smell gas

- Shut off gas supply
- Do not try to light any appliance.
- Do not touch any electrical switch; do not

use any phone in your building.

- Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s

instructions

- If you cannot reach your gas supplier,

call the fire department.

5. Always run heater with plaque control

knob 1,2,3 or at the 1,2, or 4 locked posi-
tions, Never set control knob between
locked positions. Poor combustion and
higher levels of carbon of monoxide may
result.

6. This heater needs fresh, outside air ventila-

tion to run properly. This heater has an
Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the
heater if not enough fresh air is available.
See Air for combustion and Ventilation,
pages 4
through.

7. If heater shut off, do not light again until

you provide fresh, outside air. If heater
keeps shutting off, have it service.

8. Do not run heater

- where flammable liquids or vapors are

used or stored

- under dusty conditions

9. Do not use heater if any part has been

under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the con-
trol system and any gas control which has
been under water.

10. Turn off and unplug heater and let cool

before servicing. Only a qualified service

person should service and repair heater.

11. Operating heater above elevations of

4,500 feet could cause power outage.

12. To prevent performance problems, do not

use propane/LP fuel tank of less than 100
lbs. capacity.

13. Before using furniture polish, wax, carpet

cleaner, or similar products, turn heater
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.

14. Provide adequate clearances around air

openings.

LOCAL CODES
Install and use heater with care. Follow all
local codes, use the latest edition of National
Fuel Gas Code, ANSI Z223.1/NFPA 54*

* Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY10018

National Fire Protection, Inc

Batterymarch Park

Quincy, MA 02269

PRODUCT IDENTIFICATION

UNPACKING
1. Remove the heater from carton.
2. Remove all protective packaging applied

to heater for shipment.

3. Check heater for any shipping damage. If

heater is damaged, promptly inform deal-
er where you bought heater.

3

Fig.1

WIR 2 26-06-2003 18:21 Pagina 3

This manual is related to the following products: