beautypg.com

Cooling performance with evaporator coils, 2ac14 split system air conditioner – Ducane BC User Manual

Page 3

background image

2AC14 Split System Air Conditioner

14

Cooling Performance with Evaporator Coils

Outdoor

Model

Indoor Model

SEER

EER

Rated

ARI

Capacity

1

Rated

Sensible

Capacity

CFM

Refrigerant

Connection

Refrigerant

Line Size

Indoor

Metering

Device

Piston or Field

Installed TXV

Factory

Installed TXV

Outdoor

Indoor

Suction

Liquid

Req'd

Indoor

2

Orifice

Optional

Field

Installed

Orifice

Suction

Liquid

Suction

Liquid

2AC14**18P

E(C,H,M,U)1P23N(A,B)+TXV

E(C,H,M,U)2T23N(A,B)

14.00

12.00

19,000

12,900

650

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

E(C,M,U)1P24N(A,B)+TXV

E(C,M,U)2T24NA

13.50

12.00

18,400

12,500

650

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

2AC14**24P

E(C,H,M,U)1P23N(A,B)

E(C,H,M,U)2T23N(A,B)

14.00

12.50

23,600

17,600

850

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

E(C,H,M,U)1P29NA+TXV

E(C,H,M,U)2T29NA

14.00

12.50

23,800

17,600

850

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

E(C,M,U)1P24N(A,B)+TXV

E(C,M,U)2T24NA

13.50

12.00

22,600

16,700

845

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

2AC14**30P

E(C,H,M,U)1P36N(A,B,C)+TXV E(C,H,M,U)2T36N(A,B,C)

14.00

12.00

28,600

20,900

1050

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

2AC14**36P

E(C,H,M,U)1P36N(A,B,C)+TXV E(C,H,M,U)2T36N(A,B,C)

14.00

12.00

34,600

25,300

1250

3/4

3/8

3/4 3/8

3/4

3/8

---

A2TXV01

E(C,H,M,U)1P43NB+TXV

E(C,H,M,U)2T43B

14.50

12.50

34,800

25,400

1250

3/4

3/8

7/8 3/8

3/4

3/8

---

A2TXV01

2AC14*42P

E(C,H,U)1P49NC+TXV

E(C,H,U)2T49NC

14.00

12.00

40,000

29,200

1450

7/8

3/8

7/8 3/8

7/8

3/8

---

A2TXV02

E(C,H,U)1P62NC+TXV

E(C,H,U)2T62NC

14.00

11.50

40,000

29,200

1450

7/8

3/8

7/8 3/8

7/8

3/8

---

A2TXV02

E(C,H,U)1P62ND+TXV

E(C,H,U)2T62ND

14.00

12.00

40,000

29,200

1450

7/8

3/8

7/8 3/8

7/8

3/8

---

A2TXV02

2AC14*48P

E(C,H,U)1P49NC+TXV

E(C,H,U)2T49NC

14.00

12.00

48,000

34,500

1650

7/8

3/8

7/8 3/8

7/8

3/8

---

A2TXV02

E(C,M,U)1P62NC+TXV

E(C,H,U)2T62NC

14.00

12.00

48,000

34,500

1650

7/8

3/8

7/8 3/8

7/8

3/8

---

A2TXV02

E(C,H,U)1P62ND+TXV

E(C,H,U)2T62ND

14.00

12.00

48,000

34,500

1650

7/8

3/8

7/8 3/8

7/8

3/8

---

A2TXV02

2AC14*60P

E(C,H,U)1P62NC+TXV

E(C,H,U)2T62NC

13.00

11.00

53,500

41,200

1950

7/8

3/8

7/8 3/8 1-1/8 3/8

---

A2TXV02

E(C,H,U)1P62ND+TXV

E(C,H,U)2T62ND

13.00

11.00

53,000

40,800

1950

7/8

3/8

7/8 3/8 1-1/8 3/8

---

A2TXV02

1

Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.

2

Required to achieve ARI rating.

A blower time delay is required to achieve ARI rating.

** = B, L, BC, LC
* = B, L

This manual is related to the following products: