Cooling performance with evaporator coils, 2ac14 split system air conditioner – Ducane BC User Manual
Page 3
2AC14 Split System Air Conditioner
14
Cooling Performance with Evaporator Coils
Outdoor
Model
Indoor Model
SEER
EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor
Indoor
Suction
Liquid
Req'd
Indoor
2
Orifice
Optional
Field
Installed
Orifice
Suction
Liquid
Suction
Liquid
2AC14**18P
E(C,H,M,U)1P23N(A,B)+TXV
E(C,H,M,U)2T23N(A,B)
14.00
12.00
19,000
12,900
650
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
E(C,M,U)1P24N(A,B)+TXV
E(C,M,U)2T24NA
13.50
12.00
18,400
12,500
650
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
2AC14**24P
E(C,H,M,U)1P23N(A,B)
E(C,H,M,U)2T23N(A,B)
14.00
12.50
23,600
17,600
850
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
E(C,H,M,U)1P29NA+TXV
E(C,H,M,U)2T29NA
14.00
12.50
23,800
17,600
850
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
E(C,M,U)1P24N(A,B)+TXV
E(C,M,U)2T24NA
13.50
12.00
22,600
16,700
845
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
2AC14**30P
E(C,H,M,U)1P36N(A,B,C)+TXV E(C,H,M,U)2T36N(A,B,C)
14.00
12.00
28,600
20,900
1050
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
2AC14**36P
E(C,H,M,U)1P36N(A,B,C)+TXV E(C,H,M,U)2T36N(A,B,C)
14.00
12.00
34,600
25,300
1250
3/4
3/8
3/4 3/8
3/4
3/8
---
A2TXV01
E(C,H,M,U)1P43NB+TXV
E(C,H,M,U)2T43B
14.50
12.50
34,800
25,400
1250
3/4
3/8
7/8 3/8
3/4
3/8
---
A2TXV01
2AC14*42P
E(C,H,U)1P49NC+TXV
E(C,H,U)2T49NC
14.00
12.00
40,000
29,200
1450
7/8
3/8
7/8 3/8
7/8
3/8
---
A2TXV02
E(C,H,U)1P62NC+TXV
E(C,H,U)2T62NC
14.00
11.50
40,000
29,200
1450
7/8
3/8
7/8 3/8
7/8
3/8
---
A2TXV02
E(C,H,U)1P62ND+TXV
E(C,H,U)2T62ND
14.00
12.00
40,000
29,200
1450
7/8
3/8
7/8 3/8
7/8
3/8
---
A2TXV02
2AC14*48P
E(C,H,U)1P49NC+TXV
E(C,H,U)2T49NC
14.00
12.00
48,000
34,500
1650
7/8
3/8
7/8 3/8
7/8
3/8
---
A2TXV02
E(C,M,U)1P62NC+TXV
E(C,H,U)2T62NC
14.00
12.00
48,000
34,500
1650
7/8
3/8
7/8 3/8
7/8
3/8
---
A2TXV02
E(C,H,U)1P62ND+TXV
E(C,H,U)2T62ND
14.00
12.00
48,000
34,500
1650
7/8
3/8
7/8 3/8
7/8
3/8
---
A2TXV02
2AC14*60P
E(C,H,U)1P62NC+TXV
E(C,H,U)2T62NC
13.00
11.00
53,500
41,200
1950
7/8
3/8
7/8 3/8 1-1/8 3/8
---
A2TXV02
E(C,H,U)1P62ND+TXV
E(C,H,U)2T62ND
13.00
11.00
53,000
40,800
1950
7/8
3/8
7/8 3/8 1-1/8 3/8
---
A2TXV02
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.
A blower time delay is required to achieve ARI rating.
** = B, L, BC, LC
* = B, L