Figure 6 - Minimum Mantel Clearances Without Using Hood

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

12"

(A)

18"

20"

22"

24"

All minimum
distances are
in inches

2

1/2

"

6"

8"

10"

INSTALLATION

Continued

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

Noncombustible
Material

Requirements for

Distance (A)

Safe Installation

12" or more

Noncombustible material OK.

Between 8"

24" Model:Install fire place hood accessory

and 12"

(GA6060, see Accessories, page 25).

18" Model: Noncombustible material OK

Less than 8"

Noncombustible material must be

extended to at least 8". See Between 8"

and 12", above. If you cannot extend material,

you must operate heater with flue damper

open.

Figure 7 - Minimum Mantel Clearances When Using Hood

Minimum

Noncombustible

Material

8"

Min.

12" 15"

18"

All minimum

distances are

in inches

20"

2

1/2

"

6"

8"

10"

12"

Distances to

Underside of

Mantel

Hood

(GA6050,

GA6052 or

GA6053)

Top of

Fireplace

Opening

Underside

of Mantel

Shelf

Mantel Shelf