Normal Keypad Operation:

• If the user enters a 4-digit code that is matched to one of the

25 stored codes. The STATUS light should blink twice and the

beeper should beep twice to confirm that a matched code is

entered.

• No more than 20 key presses are allowed to obtain the 4-digit

entry code.

Example:

1234 is one of the codes stored in one of the memory location.

The user can enter ‘x1234’ or ‘xxxxxxxxxxxxxxxx1234’ and

the gate should be activated (x is any key). If more than 20 key

presses is entered without matching one of the codes then the

unit’s STATUS light should be flashing rapidly and no entry will

be accepted for the next 40 seconds. The user must not enter

any code for at least 40 seconds before the unit returns to nor-

mal operation; otherwise it remains in this ‘lock-down’ mode.

Once the user enters a matched code, any subsequent key press

within the next 40 seconds will re-activate the keypad.

Delete ALL Entry Codes:

• Press and release PROGRAM button.

• Enter the Master Code then press and release PROGRAM

button.

• Enter 0, 7 then press and release PROGRAM button.

• Beeper beeps 3 times to confirm that the All Entry Codes are

deleted.

Example: Key press sequence to delete all entry codes from

memory. (for example if 3121 is the Master Code)

The round black dot is the ‘PROGRAM’ button.

If you have any questions or concerns, please contact our Technical Service Department at 1-800-543-1236 or 850-575-4144.

GTO, Inc. • 3121 Hartsfield Road • Tallahassee, Florida 32303

Telephone (850) 575-0176 • Fax (850) 575-8912 • website www.gtoinc.com

Keying Indication Summary:

Keying Error Alert Indication

Keying accepted confirmation Indication

Master Code Setting

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

STATUS light: rapid flashing

STATUS light: no light, no flashing

Permanent Entry Code

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

STATUS light: rapid flashing

STATUS light: no light, no flashing

Temporary Entry Code

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

Setting

STATUS light: rapid flashing

STATUS light: no light, no flashing

Entry Code Matching

Speaker: continuous Beep for 2 seconds

Speaker: Beep – Beep – Beep

(after non-matching 20 keying)

STATUS light: rapid flashing

STATUS light: no light, no flashing

The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be

reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by

permission only. Copyright infringement is a violation of federal law.

GTO®, GTO/PRO®, Mighty Mule® are registered trademarks of GTO, Inc. Professional Access Systems™ is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”).

All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.

3 1 2 1 0 7