beautypg.com

Lingenfelter L380180000 Lingenfelter Differential & Transmission Vent Bladder Kit v1.3 User Manual

Page 3

background image

Page

Thank you for purchasing the Lingenfelter Performance Engineering (LPE) Universal Vent Bladder

Kit. Some vehicles, under higher load or higher speed use, may have issues with fluid leaks from

the differential and/or transmission vent. This bladder kit has been designed as a solution to those

problems. The LPE Universal Vent Bladder Kit is also the perfect solution for vehicles that are

required to have a closed differential system by their sanctioning body. This product can also be

used to provide a closed vent system for vehicles that may have drivetrain components, such as

differentials and transmissions, that may become submerged in water.

The universal bladder is designed to expand to 2.25 liters, enough to account for the thermal

expansion in most light or medium duty differentials, including the AAM 241mm (9.5”) differential.

These instructions include a broad explanation on how to install the kit, as well as a specific example

(2010-2013 Camaro) that shows how the bladder may be oriented on the vehicle.

Read the entire instruction manual before beginning installation. Many of the stock parts will

be used in reassembly.

For some applications, different fittings and tube sizes may be required. Make sure to check

the size of any applicable fittings, such as the differential hose fitting, to determine the correct

fittings and hose sizes before beginning installation.

The following instructions assume that all necessary underbody components have been

removed to allow for adaquate clearance.

2.

1. The LPE differential bladder was designed

to allow for both vertical and horizontal

orientation in the vehicle. If the bladder will sit

horizontally in your application, cut the tip off of

the center breather (blue arrow). If the bladder

will sit vertically in your application, cut the tip

off of the end breather (red arrow). In both

orientations, the breather that has been cut off

must be the lowest point so that the bladder’s

contents can drain back into the differential.

Generic installation instructions for the LPE

Vent Bladder Kit:

2. In some cases, it may be desirable to

run a vent hose from the bladder to a higher

point on the vehicle. If this is required for your

application, simply cut the tip off of the breather

to connect to the differential and connect a hose

to the breather. On the other end of the hose

attach a breather fitting.