Page 8.

25. Image of fuse block base and connectors

with the fuse panel removed.

The yellow arrow shows the position of the X1

connector that will be removed in the following

steps.

wiring

harness

24. Route the wiring for the fans through the

radiator support and along the front of the truck.

Zip tie the harness along the way to hold it in

place.

26. Bring the fan harness wires that you

routed past the radiator in the previous step up

to the fuse and relay block on the driver side.

Secure the harness in place with Zip ties.

27. Using a pin depressor tool or a small

screwdriver, remove connector X1 from the

fuse block base (see fuse block diagram on

page 15 for connector numbers).

Connector X1 is the gray connector in the left

(passenger side) front corner of the fuse block

base as shown in step 25.