DIAGNOSTIC SERVICE MANUAL

DOMETIC® RM7030/RM7732

Refrigerators

SYMPTOM

CAUSE REFER TO STEP

18. No AC operation – operates on gas.

19. No gas operation – operates on AC

20. Insufficient cooling on all modes.

21. Insufficient cooling on AC – cools properly on

gas.

22. Insufficient cooling on gas – cools properly on

AC.

23. Freezes.

24. Changes preset mode.

25. Check light on.

Operation

1.1B or 1.2

AC Volts

2

Fuse

5.7

B

Heating Element

3

Upper Circuit Board

5.8

J

Wiring

8.2

Lower Circuit Board

5.9

E,F

Operation

1.1B or 1.2

LP gas

6

Manual Gas Valve

7.1

Igniter

5.5

B

High Voltage Cable

5.6

B

Electrode

5.11

Solenoid

5.4

B

Upper Circuit Board

5.8

J

Wiring

8.2

Lower Circuit Board

5.9

E,G

Ventilation

9.2

Leveling

9.1

Ambient Temperature

9.5

Air Leaks

9.3

Thermistor

5.2

Cooling Unit

9.6

Thermistor Adjuster

5.3

AC Volts

2

Heating Element

3

Lower Circuit Board

5.9

E,F

LP Gas

6

Orifice

7.2

Flue Baffle

7.5

Flue Tube

7.7

Flue Cap (RM7030 Only)

7.6

Burner

7.4

Lower Circuit Board

5.9

E,G

Thermistor

5.2

Thermistor Adjuster

5.3

Lower Circuit board

5.9

E,F,G

Upper Circuit Board

5.8

J

Operation

1.1B or 1.2

DC Volts

4

B

Wiring

8.1

Upper Circuit Board

5.8

J

Lower Circuit Board

5.9

E

DC Volts

4

Wiring

8.2

LP Gas

6

Manual Gas Valve

7.1

Solenoid

5.4

B

Orifice

7.2

Burner

7.4

Lower Circuit Board

5.9

E,G

Thermocouple

7.3

B