DECATHLON SERIES GAS FRYERS (NON-CE)

CHAPTER 3: INSTALLATION

3-7

3.5.2 Gas Conversion Procedures

DANGER

This appliance was configured at the factory for a specific type of gas. Converting

from one gas type to another requires the installation of specific gas-conversion

components.

Switching to a different type of gas without installing the proper conversion

components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A

GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be

performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.6 of this manual.


Contact factory with the following information when performing conversions:

Fryer Serial Number

Fryer Model Number

Gas Type

Operating Altitude


Conversions can only be executed by qualified, factory-authorized personnel
.



Pressure flow adjustment

(remove cover screw to access)

ON/OFF Gas-Cock Knob

Pilot gas supply connection.

Regulator Vent

Pilot pressure adjustment

(remove cover screw to access)


Typical non-CE gas valve. Gas valve shown is for electronic-ignition equipped
fryers.