Trouble- shooting, Technical service, Warning – Desa CGP10R User Manual
Page 24

24
101866
TROUBLE-
SHOOTING
Continued
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
WARNING ICON
G 001
WARNING
If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
IMPORTANT:
Operating heater where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or
textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
POSSIBLE
CAUSE
1. Heater burning vapors
from paint, hair spray,
glues, etc. (See
IMPOR-
TANT
statement above
2. Low fuel supply
3. Gas leak.
See Warn-
ing statement at
top of page
1. Not enough fresh air is
available
2. Low line pressure
3. ODS/pilot is partially
clogged
1. Gas leak.
See Warn-
ing statement at
top of page
2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak.
See Warn-
ing statement at
top of page
1. Not enough combus-
tion/ventilation air
REMEDY
1. Ventilate room. Stop
using odor-causing
products while heater is
running
2. Refill supply tank
3. Locate and correct all
leaks (see Checking Gas
Connections, page 14)
1. Refer to Air for Combus-
tion and Ventilation
requirements (page 5)
2. Contact local propane/LP
gas company
3. Clean ODS/pilot (see
Cleaning and Mainte-
nance, page 21)
1. Locate and correct all
leaks (see Checking Gas
Connections, page 14)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all
leaks (see Checking Gas
Connections, page 14)
1. Refer to Air for Combus-
tion and Ventilation
requirements (page 5)
OBSERVED
PROBLEM
Heater produces
unwanted odors
Heater shuts off in
use (ODS operates)
Gas odor even when
control knob is in
OFF position
Gas odor during
combustion
Moisture/condensation
noticed on windows