beautypg.com

Т³гж 10, Trouble shooting – Daewoo DOC-091RH User Manual

Page 10

background image

8

TROUBLE SHOOTING

1. UNIT DOES NOT

START WHEN

PRESSING 1/0 BUTTON

- Water full indicator blinks, water tank

is full.

Dump the water in the water tank.

TROUBLES

POSSIBLE CAUSES

SUGGEST REMEDIES

Reset the temperature.

Reset the temperature.

Make sure all the windows and

doors are closed.

Remove the heat sources if possible.

Connect the duct and make

sure it can function properly.

Decrease the set temperature.

Clean the air filter.

- Room temperature is higher than

the set temperature.(Heating mode)

- Room temperature is lower than

the set temperature.(Cooling mode)

- The windows or doors in the room

are not closed.

- There are heat sources inside the

room.

- Exhaust air duct is not connected or

blocked.

- Temperature setting is too high.

- Air filter is blocked by dust.

2. NOT COOL ENOUGH

Place the unit on a flat, level

ground if possible.

It is normal.

- The ground is not level or not flat

enough.

- The sound comes from the flowing

of the refrigerant inside the

air-conditioner.

4. NOISY OR VIBRATION

5. GURGLING SOUND

Switch on again after the unit has cool down.

- The automatic over heat protection

function. When the temperature at

O

O

the air outlet exceed 70 C/158 F,the

device will stop.

3. POWER SHUT OFF AT

HEATING MODE

This manual is related to the following products: