beautypg.com

Dimplex DTR350C User Manual

Installation and operating instructions, Table1, Important safety advice

background image

Table1

Model

Rails

Watts

Weight (kg)

DTR175 W/C

12

175

4.4

DTR350 W/C

18

350

7.9

Important Safety Advice

WARNING - THE SURFACE OF THIS RADIATOR CAN BE HOT.

In order to be effective the towel rail will get hot, however
momentary contact with any part of it should not cause
injury.

CAUTION - This appliance is not intended for use by
chidren or other persons without assistance or
supervision if their physical, sensory or mental
capabilities prevent them from using it safely. Children
should be supervised to ensure that they do not play
with the appliance.

Precautions should be taken to ensure that prolonged
contact with the towel rail cannot occur. Particular care
should be taken in confined areas where accidental
prolonged contact with the rail could be more likely to
occur.

This appliance should only be used to dry fabrics washed
in water using commonly available detergents.

IMPORTANT - If the towel rail is to be installed in a place
used by the public, a warning notice should be placed
adjacent to the rail advising that the surface can be hot.

WARNING - In order to avoid a hazard for very young
children, this appliance should be installed so that the
lowest heated rail is at least 600mm above the floor.

General

The DTR towel rail is designed to provide an all year round service
for airing towels and articles of clothing. It is not intended to provide
a sole heating service, but the larger model will take the chill off an
av

erage size bathroom, lavatory or en suite. Your rail will be in one

of two sizes and will have either silver chromium plated or white
stove-enamel finish.

No routine maintenance is necessary apart from occasional cleaning.

Both models are splashproof to IPX4 standard.

Electrical

The electrical installation of this towel rail must be carried out by a
competent electrician in accordance with the current I.E.E Regulations
for Electrical Equipment. The towel rail is suitable for use on an A.C.~
electrical supply. Before installation check that the supply voltage
corresponds with that marked on the rail.

IMPORTANT - The wires in the mains lead are coloured in
accordance with the following code:

BLUE

-

NEUTRAL

BROWN

-

LIVE

This appliance must only be used on A.C. mains supply of 230/240
Volts~.

Installation

If fitted in a room containing a bath or shower, to comply with the
current I.E.E. Regulations, a cable outlet will be
necessary with the supply to the heater controlled by a
double-pole pull-cord switch having a contact separation of 3mm in
each pole. The body of the switch should be situated as to be
normally inaccessible to a person using a bath or shower. Should
Equipotential Earth Bonding be required the earthing conductor in the
supply cord is deemed to provide the supplementary bonding
connection (see Regulation 547-03-0, ’16th’ Edition I.E.E. Wiring
Regulations.

IMPORTANT - Protect the electrical connection whilst
handling the towel rail.

The towel rail must be permanently fixed to the wall using the wall
brackets supplied. The rail must be mounted vertically as shown
observing the minimum clearances stated.

WARNING - The towel rail is heavy. Care must be taken when lifting
and fitting the towel rail.

Wall mounting

The wall mounting accessory pack contains:

(a)

4 mounting brackets

(b)

1 allen key

(c)

4 wall mounting screws, washers and wall plugs

(d)

4 hex. stud screws

IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Dimensions

(millimetres)

Installation and Operating Instructions

DTR Towel Rails
Models : DTR175W, DTR175C, DTR350W & DTR350C

Fig. 1

08/50116/1 (UK) Issue 1

DTR 350

602

100 min.

843

shelf

This manual is related to the following products: