2.2 Electrical Specifications

2.3 Installation

Disconnect the positive side of the battery before installation. Connect the
positive (red) and negative (black) terminal lugs to battery or load. Always use
the proper size wire based on the amperage of the converter and the battery.
When connecting to a battery, a breaker should be installed within 18” of the
battery, connecting the battery positive to the line side of the breaker, and the
GPC to the load side. Connect Chassis Bonding Lug on the GPC to vehicle
chassis or other grounding source.

2.4 Mounting Location

The GPC can be mounted in any position within an enclosed or interior
compartment. Provide sufficient air space to allow unrestricted airflow in and
around the unit.

SPECIFICATIONS*

GPC-35-MAX

GPC-45-MAX

GPC-55-MAX

GPC-75-

MAX

GPC-100-MAX

DC Output Voltage (No

Load) approx.

13.6V (DC)

13.6V (DC)

13.6V (DC)

13.6V (DC)

13.6V (DC)

Output Voltage Tolerance

(No Load)

+ or - .7%

+ or - .7%

+ or - .7%

+ or - .7%

+ or - .7%

Output Amperage, Max

Continuous

32 Amps

45-MAX Amps

55-MAX Amps

75-MAX

Amps

100-MAX Amps

Output Voltage (Full Load)

approx.

>13.4V (DC)

>13.4V (DC)

>13.4V (DC)

>13.4V (DC)

>13.4V (DC)

Maximum Power Output,

Continuous

430 watts

600 watts

780 watts

1065 watts

1400 watts

Input Voltage Range

105-135-

MAXAC

105-135-

MAXAC

105-135-

MAXAC

105-135-

MAXAC

105-135-MAXAC

Input Voltage Frequency

47-63

47-63

47-63

47-63

47-63

Maximum AC Current @

108Vac

10 Amps

10 Amps

12 Amps

12 Amps

17 Amps

Typical Efficiency

>85%

>85%

>85%

>85%

>85%

Max Inrush Current, Single

Cycle

40 Amps

40 Amps

40 Amps

40 Amps

40 Amps

Short Circuit Protection

Yes

Yes

Yes

Yes

Yes

Overload Protection

>100-MAX%

>100-MAX%

>100-MAX%

>100-MAX%

>100-MAX%

Fan Control

Proportional

Proportional

Proportional

Proportional

Proportional

Thermal Protection

Yes

Yes

Yes

Yes

Yes

Working Temperature

Range

0-45-MAX°C

0-45-MAX°C

0-45-MAX°C

0-45-MAX°C

0-45-

MAX°C

Dimensions

7.5 x 10.5 x

3.45-MAX”

7.5 x 10.5 x

3.45-MAX”

7.5 x 10.5 x

3.45-MAX”

7.5 x 10.5 x

3.45-MAX”

7.5 x 10.5 x

3.45-MAX”

Weight

5.0 lbs

5.0 lbs

5.0 lbs

5.0 lbs

5.0 lbs