1. Introduction

The Go Power! Inverter series provides mobile power for people on the go. Run
standard AC appliances wherever you travel. Silent, lightweight and simple to use, Go
Power! Inverters can be used in a wide range of applications including remote homes,
RVs, boats and long haul trucks. It will operate most televisions and VCR’s, personal
computers and small appliances including drills, sanders, grinders, mixers, blenders and
microwaves.

To get the most out of your power inverter, it must be installed and used properly.
Please read the instructions in this manual before installing and using your

inverter.

2. Specifications

Model No.

GP-1000-12 V

Continuous Output Power

1000 W

Surge Rating

1300 W

Output Waveform

Modified Sine Wave

Output Voltage

115 VAC RMS +5%/-10%

Output Frequency ±1%

60 Hz

Input Voltage

10-15 VDC

Efficiency

80 - 90%

No Load Current Draw

0.2 A

Protection

Overload, overtemperature,
overvoltage, and low voltage

Low Battery Alarm ± 2%

10.5 V

Low Battery Shut-Down ± 2%

10.0 V

Operating Temperature Range

0 - 40°C / 32°F - 104°F

Storage Temperature Range

-30°C - 70°C / -22°F - 158°F

Cooling

Thermostatically controlled fan

AC Receptacle

2

Dimensions (LxWxH) mm

284 x 147 x 71

inches

11.2 x 5.8 x 2.8

Weight kg / lbs

2.0 / 4.2

Warranty

1 year

Inverter Install Kit

GP-DC-Kit 2

Go Power! Modified Sine Wave Inverter

Owner’s Manual

Go Power! Modified Sine Wave Inverter

Owner’s Manual

10

3

Problem and Symptoms

Low AC output voltage
95-105 VAC.

No output voltage, LED
indicator is orange.

No output voltage, LED
indicator is orange.

No output voltage, LED
indicator is orange

No output voltage, no
lights.

No output voltage, no
lights.

No output voltage, voltage
indication above 15V.

Low battery alarm on all the
time, LED indicator is
orange.

Possible Cause

Using standard voltmeter

Overload

Low DC input voltage
Inverter switched off.
No power to inverter.

Internal operating
temperature too high.

Internal circuitry failure

Reverse DC polarity
connection

High input voltage

Poor DC wiring, poor
battery condition.

Solution

Use true RMS averaging
meter.

Turn off. Reduce load, turn
on.

Recharge battery, check
connections and cable.

Allow inverter to cool off.
Reduce load if continuous
operation required.

Have original sales vendor
technician check and
replace if under warranty.

Reverse DC polarity
connection is not covered
under warranty

Make sure that inverter is

connected

t

o 12 V battery.

Check regulation of charging
system.

Use proper cable and make
solid connections. Use new
battery if batteries are poor.

Move the television as far away from the power inverter as possible.

Keep the cables between the battery and the power inverter as short as

possible and twist them together with about 2 to 3 twists per foot. This
minimizes radiated interference from the cables.