General data – Glow-worm Hideaway 50BF User Manual

Page 5

background image

5

221692B

General Data

A

B

C

D

E

F

G

H

J

K

L

M

N

P

mm

300

118

558

294

225

533

3

300

445

121

132

664

292

398

in.

11

3

/

4

4

5

/

8

22

11

1

/

2

8

7

/

8

21

1

/

8

11

3

/

4

17

1

/

2

4

3

/

4

5

1

/

4

26

1

/

8

11

1

/

2

15

5

/

8

GENERAL DIMENSIONS - given in millimetres (Approx. inches)

Diagram 1.1

0684

K

Refer to BOILER CASING

HEIGHT diagram

P

M

L

H

J

D

C

B

E

G(MIN.)

F(MIN.)

C

L

C

L

A SPECIAL TOP CASING

TO SUIT 600mm (23

5/

8

in.)

WORKTOPS IS AVAILABLE

A

WATER CONNECTIONS

Rc1 (1in. B.S.P.T.)

WATER CONNECTIONS Rc1 reduced
with DISTRIBUTOR TUBE to
Rc

3/

4

(

3/

4

in. B.S.P.T.) (pumped return)

GAS CONNECTION

Rc

1/

2

(

1/

2

in. B.S.P.T.)

RANGE RATING

NOMINAL

kW

HEAT INPUT
(GROSS)

Btu/h

15.01

16.85

18.66

51,215

57,475

63,675

min

medium

max

BURNER

mbar

SETTING
PRESSURE

in.w.g

(HOT)

9.8

12.1

14.8

3.9

4.9

5.9

NOMINAL

kW

HEAT
OUTPUT

Btu/h

11.72

13.19

14.65

40,000

45,000

50,000

205729

INJECTOR

Sheet Metal Parts

WARNING. When installing or servicing this boiler, care should
be taken to avoid any possibility of personal injury when
handling the edges of sheet metal parts.

Important Notice

This boiler is for use only on G20 gas.

Wherever possible, all materials, appliances and components
to be used shall comply with the requirements of applicable
British Standards.

Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

1.1 Data

Approximate weight of complete boiler : 79kg (174lb)

Water content :

5.76 litre (1.27gallons)

Gas connection :

Rc

1

/

2

(

1

/

2

in BSPT)

Water connection :

Rc1 (1in BSPT)

Injector

50B : 3.60mm

Electrical supply :

240V~50Hz, fused 3A

Burner :

Aeromatic

All dimensions are given in millimetres (except as noted).

The Seasonal Efficiency Domestic Boilers UK (SEDBUK)
is 71.4%.

The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

1.2 Range Rating

This boiler is range rated and may be adjusted to suit individual
system requirements. The table gives settings and outputs.

The boiler input as supplied is preset to the maximum heat input
and should be adjusted to suit system requirements.

The indicator arrow should be stuck on the data label to indicate
the adjusted setting. The arrow is supplied in the loose items
pack.

C

L