Installation, 5 appliance location, 6 appliance installation – Glow-worm Clearly Hybrid - Universal Module User Manual
Page 10: 1 scope of delivery, 2 recommendations before installing
0020096324_01.1 - 09/10 - Glow-worm
- 8 -
INSTALLATION
5 Appliance
location
• Before choosing a site for the appliance, carefully read the
safety warnings and installation manual.
• Ensure that wall to which the appliance will be mounted on is
structurally safe in order to support the weight of the appliance.
• Ensure that the space that the appliance is to be installed
within allows the appliance to be installed and the clearances
maintained. This will ensure that the connections to the water
can be accessed and inspected (see chapter Clearances).
• The appliance must be installed in a room protected from
freezing. Take all necessary precautions.
• Explain these requirements to the appliance user.
6 Appliance
installation
6.1
Scope of delivery
5.1
5
5.2
4.5
4.4
4.3
4.2
4.1
4
1
3
3.1
5.3
5.4
5.5
2
Key
1
Hydraulic module
(x1)
2
Hydraulic module cover
(x1)
3
Connector plate (*)
(x1)
3.1
Connector plate (Réf. 0020093953)
(x1)
4
Elements supplied with the connector plate (*)
4.1
Safety valve pipe
(x2)
4.2
Bag of seals
(x1)
4.3
Bag of connectors
(x1)
Heat pump return adaptor
(x1)
Heat pump outlet adaptor
(x1)
Heating return adaptor
(x1)
Heating outlet adaptor
(x1)
Boiler return adaptor
(x1)
Boiler outlet adaptor
(x1)
4.4
Bag of seals
(x1)
Seal ¾"
(x12)
4.5
Connector strip
(x1)
5
Bag of documents
(x1)
5.1
Proof of purchase card
(x1)
5.2
Guarantee request
(x1)
5.3
User manual
(x1)
5.4
Installation manual
(x1)
5.5
Drilling template
(x1)
(*)
Ordered separately
• Check the contents of the packages.
6.2
Recommendations before installing
6.2.1
Heating circuit design
The heat
emitters
may be low temperature (
under-
fl oor heating,
low-
temperature
radiator ...)
or
high temperature (cast iron
radiator ...).
The pipe
work is
to be determined using a fl ow / pressure curve.
The distribution will be determined by the fl ow corresponding to
the power actually required, regardless of the maximum power
that can be provided by the installation’s generators.
Installation pipework must be designed and installed to ensure
venting of air from the system is possible.
The total volume of water for the heating circuit depends,
among other factors, on the cold static load of the boiler’s
expansion tank. It is recommended that a drainage valve be
installed at the lowest point of the installation.
Thermostatic radiator valves should be fi tted to all radiators
with the exception of rooms in which
the room thermostats are
installed.
-
In existing installations, the radiator circuit must be fl ushed
prior to installing the new appliance.
-
If a system component is not put in place immediately,
protect the different connections so that the plaster and paint
does not spoil water tightness for later connecting.