beautypg.com

Service, troubleshooting and repair, Ardisam, Ordering repair parts – EarthQuake W1000 User Manual

Page 9: Service information, Troubleshooting

background image

ARDISAM

.com

Page 9

800-345-6007

EARTHQUAKE, Division of Ardisam, Inc.

ORDERING REpAIR pARTS

Parts can be obtained from the store where your mini log
splitter was purchased or direct from the factory. To order
from the factory, call or write to:

Please include the following information with your order:

1. Part numbers

2. Part description

3. Quantity
4. Model number and serial number

Ardisam, Inc.

1690 Elm Street, Cumberland, WI 5489

Phone (715) 8-415 Main Fax (715) 8-3

800-345-6007

Email [email protected]

SERvICE INFORMATION

In the event you experience trouble operating your mini
log splitter, follow the suggestions in the troubleshooting
guide in this section.
The guide will help you pinpoint the causes of common
problems and identify remedies.
For more complicated repairs you may want to rely on
your retailer, an authorized mechanic, or Ardisam, Inc.
(contact your retailer for a list of authorized mechanics in
your area). A parts catalog is included in this section.
We will always be glad to answer any questions you
have, or help you find suitable assistance. To order parts
or inquire about warranty, call or write us at the address
found in the next column, under the section ordering
repair parts.

SERvICE, TROUblEShOOTING AND REpAIR

IN CASE OF A SERVICE PROBLEM, DO NOT SEND
UNIT BACK TO RETAILER. CONTACT ARDISAM,
INC. AT 1-800-345-6007. WE WELCOME YOUR

TROUblEShOOTING

Problem

Possible cause

Remedy/Action

Fails to split logs

The log pusher moves with a jerking
motion, makes an unfamiliar noise or
vibrates excessively

Oil leak occurs around cylinder ram or
from other points

1. Refer to Log Splitter Operation Sec-
tion for perfect log loading
2. Reduce the log size before splitting
on the log splitter
3. Refer to Sharpening Wedge Section
to sharpen the cutting edge
4. Locate leak(s) and contact the dealer
5. Contact the dealer

1.

Check oil level for possible oil

refilling. Contact the dealer.

1. Loosen bleed screw 3-4 rotations
before operating the log splitter
2. Tighten the bleed screw before mov-
ing the log splitter
3. Tighten the oil drain bolt with dipstick
4. Contact the dealer

1. Log is improperly positioned

2. The size or hardness of the log exceeds
the capacity of the machine
3. Wedge cutting edge is blunt

4. Oil leaks

5. Unauthorized adjustment was made onto
the maximum pressure limiting screw

1.

Lack of hydraulic oil and excessive

air in the hydraulic system

1. Air sealed in hydraulic system while oper-
ating
2. Bleed screw is not tightened before mov-
ing the log splitter
3. Oil drain bolt with dipstick is not tight
4. Hydraulic control valve assembly and/or
seal(s) worn

ARDISAM