Specifications and electrical requirements – EarthQuake W1200 User Manual
Page 5
![background image](/manuals/735602/5/background.png)
Operator's Manual
5-Ton Electric Log Splitter W1200
Check for parts online at
www.getearthquake.com or call 800-345-6007 M-F 8-5
5
SPECIFICATIONS AND ELECTRICAL REQUIREMENTS
APPLICATION CONDITIONS
The Earthquake 5-Ton Electric Log Splitter has been designed
as a home use model only. It is designed for operating at ambi-
ent temperatures between 40° F. and 105° F. The log splitter
can be stored or transported under ambient temperatures
between -10° F. and 130° F.
SPECIFICATIONS
Model Number
W1200
Motor
120V~50Hz
1500W IP54
Circuit Protection
Requirements
20 Amps
(Amperes)
Log Capacity
Diameter *
2 - 10 inches
Length
20 inches
Splitting Force
5 ton
Hydraulic Pressure
2,300 psi
Hydraulic Oil Capacity
3.75 quarts
Overall Size
Length
37 inches
Width
11 inches
Height
20 inches
Weight
99 lb
*The diameter of the log is not indicative - a small log can be difficult
to split when it contains knobs or a particularly tough fiber. On the
other hand, it may not be difficult to split logs with regular fibers
even if its diameter exceeds the maximum diameter described in the
specifications chart.
ELECTRICAL REQUIREMENTS
Connect the main leads to a standard 110V ±10% electrical
supply which has protection devices under-voltage, over-volt-
age, over-current, as well as a ground fault circuit interrupter
(GFCI) or a ground fault interrupter (GFI) with a maximum
residual current of 0.03A.