Installtion intructions – Danby DWC508BLS User Manual
Page 4
Carpenters
Square
Measuring
Tape
Level
Drill & Hole Saw set
Gloves
Safety Glasses
Flashlight
Electrical Access
Cabinets
Square
and
Plumb
34 3/4”
From
Underside
of
Countertop
to Floor
24”
6”
24”
Min.
1-
1
/2” dia. hole
*if electical
outlet is in
adjacent
cabinetry
2”
TOOLS YOU
WILL NEED
FOR YOUR SAFETY:
While performing installations described in
this section, gloves, safety glasses, or goggles
should be worn.
PREPARING THE
ENCLOSURE
ELECTRICAL REQUIREMENTS: The appliance must be connected to an
individual, properly grounded electrical outlet, protected by a 15 or 20 ampere circuit
breaker or time delay fuse.
• It is recommended that you do not install the wine cooler into a corner (i.e. directly beside a wall). This is to
allow the door to have a greater then 90° opening swing. A limited door swing may lead to damaging the
door gasket.
• The rough cabinet opening must be on a level floor area and at least 24” deep by 24” wide. The opening
should also have a height of at least 34 3/4”.
• The electrical oulet may be positioned from within either side of the adjacent cabinetry, or the rear of the
shaded area (as shown in Fig E).
• If the electrical outlet is located inside the adjacent cabinetry, cut a 1-1/2” diameter hole to admit the power
cord. If the cabinet wall is metal, the hole edge must be covered with a bushing or grommet.
INSTALLTION INTRUCTIONS
Fig E
3