beautypg.com

Da-Lite ViewShare Tensioned Advantage Electrol User Manual

Page 7

background image

7

240V Wiring Diagram

IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, EVEN if a third party control system is
used. Therefore, it is advised to wire the switch or provide a
4-conductor connection that is accessible.

Wall Switch Installation for 220/240V Screens

ILT RJ-9 Pin-Outs

(Tab Is Facing Up)

Ground Common

IR or Up

+5V

Data or Down

Red

White

Black

240V Wiring Diagram with Optional Built-in Video Projector Interface

CAUTION: The projector must be turned off before
connecting the trigger wires to the projector. Failure to do so
may damage the controller.

ATTENTION: Le projecteur doit être éteint avant de brancher
les fils de déclenchement à celui-ci. Tout manquement à
cette instruction pourrait endommager le contrôleur.

1. Use 2-conductor 20-24 gauge wire to extend the low voltage

connection from the projector’s 5 or 12-volt screen trigger output
to the length required to reach the VPI. When extending the low
voltage connection from the projector’s screen trigger output, be

sure to maintain the proper polarity. The red wire from the VPI is
the “signal” and the black wire from the VPI is the “ground”.

2. Connect the wires from the VPI that are labeled “Low Voltage

Connection” to the end of the extended screen trigger wires
above.

IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, EVEN if a third party control system is
used. Therefore, it is advised to wire the switch or provide a
4-conductor connection that is accessible.

240VAC/ 50Hz
Power Source

5/12 Volt Screen Trigger
on Projector

Red

Red

White

Black

Black

Brown (Hot)

Green/Yellow (Ground)
Brown (Down)
Blue (Common)
Black (Up)

Green/Yellow
(Ground)

Blue (Common)

Front of Wall

Switch

Back of

Wall Switch

UP DN

UP +5

V

COM DN

UP

STOP

DOWN

GND

+5V

3-POSITION
SWITCH

RJ9

RJ9

RJ9

Motor

Front of Wall

Switch

Splitter

Dry Contacts

Back of

Wall Switch

Green

Brown (Hot)

Blue (Common)

NOTE: Ground–Must be

Connected to Building
Ground

Ground to Case

Green

Power Input

240VAC / 50Hz

Green