5V

Screen Adjustment For 120V Screens With A Built-In Low Voltage Control or VPI

1. Locate the wall switch and remove the cover plate from

the 3-button wall switch and remove the switch from the
junction box.

2. Locate the two tactile buttons on the back of the switch. They

are square silver with black round buttons. See Figure 4 (VPI)
or Figure 5 (LVC) for diagram.

3. To adjust the down limit switch, press and hold the down

tactile button until the LED on back of switch turns solid red.
This will put the motor in limit set mode. Turn the wall switch
over and use the down button on front of switch. Press and
hold until the desired travel position is reached. If you travel to
far down you can press the up to move the screen upward. If
you press and let go of either up or down button the motor
will do a small jog in that direction for finer adjustment of
screen. Once desired position is reached turn switch over
press and hold down tactile button until the LED on back of
switch blinks red twice. The down limit is now set.

4. To adjust the up limit switch, press and hold the up tactile

button until the LED on back of switch turns solid green. This
will put the motor in limit set mode. Turn the wall switch over

and use the up button on front of switch. Press and hold until
the desired travel position is reached. If you travel to far up
you can press the down to move the screen downward. If you
press and let go of either up or down button the motor will do
a small jog in that direction for finer adjustment of screen.
Once desired position is reached turn switch over press and
hold up tactile button until the LED on back of switch blinks
green twice. The up limit is now set.

5. To test limit switch setting, press and release the up or down

button on the wall switch to operate the screen.

6. Replace switch and cover plate on the wall.

NOTE: If the screen is in limit set mode and no buttons are
pushed for 20 seconds, the LED on the back of the wall switch
will turn off, the motor will return to run mode and no changes
will be saved. If this occurs, return to step 3 for down limit
adjustment or step 4 for up limit adjustment.

IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 3-conductor connection that is accessible.

Figure 5

120V Wiring Diagram with Optional Built-In Low Voltage Control

Ground–Must Be
Connected To Building
Ground

IMPORTANT NOTE:

The wall switch is REQUIRED to make any limit switch
adjustments, EVEN if a third party control system is used.
Therefore, it is advised to wire the switch or provide a
3-conductor connection that is accessible.

UP

STOP

DOWN

Power Input 120VAC / 60HZ

Green (Ground)

Black (Hot)

White (Common)

Power Wire

Data Cable

RJ-45 Jack

RJ-45 Receptacle

RJ-22 Outputs

RJ-22
Jack

RJ-22

Inputs

RJ-22

Jack

LED

Up Limit

Tactile

Button

Down

Limit

Tactile

Button

Front Of

Wall Switch

Back Of

Wall Switch

Dry Contacts

BUS

BUS

COM 5V

BUS

3-conductor 20-24 gauge wire can be used in place of the
supplied RJ-14 cable to connect the wall switch. Connect the
BUS terminals on the wall switch to the corresponding BUS
terminals on the splitter board.

RJ-14 Pin-Outs

(Tab Is Facing Up)

Supplied RJ-14 cable

Bus (RP Data)

RQ Data

+5V

Ground

White

Green

Red

Black

RJ-22 Pin-Outs

(Tab Is Facing Up)

Standard RJ-22 can be used in place of RJ-14

Bus (RP Data)

+12V

RQ Clock

RQ Data

+5V

Ground

Yellow

Green

Red

Black

White

Blue

RJ-45 Pin-Outs

(Tab Is Facing Up)

+12V

Manual 2

Ground

Manual 1

RQ Clock

Bus (RP Data)

RQ Data

+5V

Blue

Green

Yellow

Red
Black
Orange
Purple

Brown