Clay Paky V.I.P. DIA User Manual
Page 4

8
TECHNICAL DATA
6
Power supplies available
• Version with built-in power factor
correction:
- 220 - 240V 50Hz
- 200V 50Hz - 230V 60Hz
- 200 - 220V 60Hz
- 260V 50Hz
• Version without built-in power factor
correction:
- 220 - 240V 50Hz
- 200V 50Hz - 230V 60Hz
- 200 - 220V 60Hz
- 260V 50Hz
- 120V 60Hz
- 100V 50Hz
- 100V 60Hz
The projector is designed to operate at
the mains frequency and voltage given
on the electrical data label on the back
of the appliance.
Input power
• Versions with built-in power factor
correction: 450VA at 230V 50Hz
(standard power factor correction 35µF).
• Versions without built-in power factor
correction:
800VA at 230V 50Hz.
Lamp
Metal halide supplied with special
built-in power supply unit.
• Type HTI 300W
- Connection SFc 10-4
- Colour temperature 6,500 K
- Luminous flux 22,000 lm
- Average life 750 h
- Any working position
• Type HMD 300W
- Connection SFc 10-4
- Colour temperature 5,700 K
- Luminous flux 20,000 lm
- Average life 3,000 h
- Working position p45
Optical unit
• Base in die-cast aluminium.
• Twin lens condenser.
• Spherical reflector with a high
luminous efficiency.
Lens units
• Standard: 1:2,4/100 mm (30,9°)
• Optional: 1:2,8/45 mm multi-lens (64,2°)
• Optional: 1:2,8/60 mm multi-lens (45,8°)
• Optional: 1:2,8/85 mm multi-lens (34,4°)
• Optional: 1:2,8/120 mm multi-lens (24,1°)
• Optional: 1:3,5/150 mm multi-lens (19,5°)
• Optional: 1:4/165 mm (17,2°)
• Optional: 1:4,4/200 mm (14,3°)
• Optional: 1:3,5/70÷120 mm zoom (39,5°÷22,9°)
Safety Devices
• Power supply automatically cut off in
the event of overheating.
• Power supply cut off on opening the
cover.
• Shor t-circuiting protection on the
accessory holder guides.
Cooling
By forced ventilation with the axial fan
(projector body) and radial fan (slide
holder accessory).
Body
• In die-cast and extruded aluminium.
• Epoxy powder painting.
Mounting
• Bracket in steel painted with epoxy
powders.
• Three installation positions with a step
of 25 mm (0.98”).
• Bracket adjustable on 120°.
Working position
Operation in any position, limited to the
specifications of the lamp used.
Weights and dimensions
Versions 200-240V with PFC: 7,8 kg
(17 Ibs 3 ozs).
Versions 200-240V without PFC: 7,3 kg
(16 Ibs 1 ozs).
Versions 100-120V without PFC: 10,2 kg
(22 Ibs 7 ozs).
A
At
(10.04”) 255
(12.09”) 307
(6.38”)
162
(8.07”)
205
(6.69”)
170
At
A
21.22”
539 mm
14.84”
377 mm
200-240V
with PFC
18.98”
482 mm
12.60”
320 mm
200-240V
without PFC
21.22”
539 mm
14.84”
377 mm
100-120V
without PFC
TROUBLESHOOTING
5
No mains supply.
Check the supply socket is
powered and/or fuse
conductivity.
THE PROJECTOR WILL NOT SWITCH ON
NO MOTOR-DRIVEN ACCESSORY WORKS
TROUBLE
DEFECTIVE PROJECTION
REDUCED BRIGHTNESS
POSSIBLE CAUSES
CHECKS AND REMEDIES
•
•
•
•
•
•
•
•
Lamp exhausted or defective.
Replace the lamp.
(See instructions).
No power on the guides.
Call an authorized technician.
The accessory motors fail to
work.
Call an authorized technician.
Lenses or reflector broken.
Call an authorized technician.
Dust or grease deposited.
Clean. (See instructions).