Information menu – Clay Paky ALPHA PROFILE 700 “ST” User Manual
Page 21
21
ALPHA PROFILE 700 &
“
ST
”
Continue
➔
SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing
F
you are allowed to reset the SYSTEM ERRORS list.
A confirmation message (Are you sure you want to clear error list ?)
appears on the display.
2) Select YES to reset the list or NO to go back.
FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working life hours (from manufacture to date).
Partial counter
Counts the number of partial projector working life hours since the
last reset to date.
2) Press
F
to reset partial projector working hours a confirmation
message (Are you sure?) appears on the display.
3) Select YES to reset partial projectors counter or NO to keep the
current setting and return to the top menu level.
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.
2) Press
F
to reset partial lamp working hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting and
return to the top menu level
MACRO EFFECTS
It lets you select the “Macro Effects” set up from the two available.
1) Press
F
the current setting appears on the display.
2) Use the UP
B
and DOWN
C
keys to select one of the following set-
tings:
Macro group size
It lets you set the number of projectors to be included in the macro mode
operation.
1) Press
F
2) Use the UP
B
, DOWN
C
, RIGHT keys to set the number of projec-
tors to be included in the “Macro Effect” operation.
3) Press
F
to confirm the selection or LEFT
D
to keep the current set-
ting.
Macro fixture Id
It lets you attribute an ID address to the projector for the phase displace-
ment for the scene’s starting time in Macro mode.
1) Press
F
2) Use the UP
B
and DOWN
C
keys to select one of the following settings:
Fixed to X. (to assign to all the projectors to be included in the Macro
operation).
Auto by DMX Address: According to the DMX address, it automatically
detects the starting sequence of the scene in the Macro mode (to assign
to all the projectors to be included in the Macro operation).
3) Press
F
to confirm the selection or LEFT
D
to keep the current set-
ting.
LAMP DIMMING
This lets you select the lamp “dimmer” mode, selecting one of the two
available modes:
• Electronic: Default setting, the lamp is electronically “dimmed” from
100% to 80% and mechanically for the rest of the range. Visually, the
Dimmer curve is high performance but a slight flicker could be noted in
INFORMATION MENU
Load
Preset 2
Save To
Preset 2
User
Preset 2
Load
Preset 3
Save To
Preset 3
User
Preset 3
Lamp
Hours
Total
XXX
Partial XXX
Reset...
Information
System
Errors
Fixture
Hours
Total
XXX
Partial XXX
Reset...