beautypg.com

33 technical information, 33 cause and solution of problems – Clay Paky ALPHA WASH 1500 User Manual

Page 33

background image

33

ALPHA WASH 1500

660

(25.98")

570

(22.44")

488

(19.21")

785

(30.91")

261

(10.28")

500

(19.69")

480

(18.90")

640

(25.20")

Power supplies available
200-240V 50/60Hz

Input power
2000VA a 230V 50Hz.

Total output
Max 46000 lumens.

Lamp
Discharge lamp.
• Type HTI 1500W/60/P50-L Lok-it Osram (L10102)

- Cap PGJ50
- Colour temperature 6000 K
- Luminous flux 135000 lm
- Average life 750 h
- Any working position

Motors
21 stepper motors, operating with microsteps,
totally microprocessor controlled.

Optical unit
Elliptic reflector with high luminous efficiency

Channels
Max 23 control channels.

Inputs
• DMX 512
• Ethernet

Moving head
• Movement by means of two stepper motors, con-

trolled by microprocessor.

• Automatic repositioning of PAN and TILT after

accidental movement not controlled by control
unit.

• Angle:

- PAN = 540°
- TILT = 252°

• Maximum speeds:

- PAN = 4.0 sec (360°)
- TILT = 3.2 sec (252°)

• Resolution:

- PAN = 2.11°
- PAN FINE = 0.008°
- TILT = 0.98°
- TILT FINE = 0.004°

IP20 protection rating
• Protected against the entry of solid bodies larger

than 12mm (0.47”).

• No protection against the entry of liquids.

Safety Devices
• Bipolar circuit breaker with thermal protection.
• Automatic break in power supply in case of

overheating or failed operation of cooling system.

Cooling
Forced ventilation with axial fans.

Body
• Aluminium structure with die-cast plastic cover.
• Two side handles for transportation.
• Device locking PAN and TILT mechanisms for

transportation and maintenance.

Working position
Working in any position.

Weight
44.90 Kg (98lbs, 12ozs).

TECHNICAL INFORMATION

CAUSE AND SOLUTION OF PROBLEMS

THE PROJECTOR WILL NOT SWITCH ON

PROBLEMS

ELECTRONICS NON-OPERATIONAL

DEFECTIVE PROJECTION

REDUCED LUMINOSITY

POSSIBLE CAUSES

CHECKS AND REMEDIES

No mains supply.

Lamp exhausted or defective.

Signal transmission cable faulty or disconnected.

Incorrect addressing.

Fault in the electronic circuits.

Lenses or reflector broken

Dust or grease deposited.

Check the power supply voltage.

Replace the lamp. (See instructions).

Replace the cables.

Check addresses (see instructions).

Call an authorised technician.

Call an authorised technician.

Clean (see instructions).