Motor and fan, Electrical, Bleed off – Bonaire Cool Change (Newtronics) User Manual
Page 13: Pump, Water distribution, Owner’s manual

Integra
Owner’s Manual
Page 13
Motor and Fan
Check that the fan spins freely and that there is no build up on the blades.
Electrical
No general maintenance is required to the electrical system.
A Qualified Electrician should only carry out electrical connections and maintenance.
Bleed Off
The bleed rate should be checked to ensure it is adequate and that there is no build
up of mineral deposits in or on your air conditioner. White deposits indicate high
mineral content and the Bleed Rate should be increased. If it is at maximum and the
deposits are still forming, then more regular maintenance is required.
Pump
Check the pump spins freely and that the strainer is clean.
Water Distribution
Check the water distribution system for blockage. Check the delivery tube for kinks
or holes. Check that the clamps are secure and in place.