3 outer dimensions and technical data, Englisch – Austroflamm Polly User Manual
Page 44

english
42
Polly
3 Outer dimensions and technical data
Nominal thermal output (NWL)
8 kW
Partial-load thermal output
2.4 kW
Space heating capacity
55 – 190 m³
Degree of efficiency
> 90%
CO content at NWL
<180 mg/Nm³
CO content at partial-load
155 mg/Nm³
Flue gas temperature at NWL
150 °C
Flue gas mass flow rate at NWL
4.4 g/s
Flue gas mass flow rate at partial-load
3.2 g/s
Holding capacity, full tank
26 kg / 40 l
Fuel
Pellets
Pellet consumption min./max
0.6 – 1.8 kg/h
Autonomy min./max
approx. 12 - 40 h
Air connector Ø
80 mm
Flue connector Ø
100 mm
Current upon switching on
300 W
Operating current
50 W
Voltage / current frequency
230 V / 50 Hz
Voltage fluctuations
0.9 - 1.1 of the rated voltage
Frequency fluctuations
0.99 - 1.01 of the rated frequency, constant
0.98 - 1.02 short-term
Dimensions
H x W x T
1100 x 526 x 498 mm
Weight
150 kg
Minimum spacing
side
150 mm
rear
100 mm
front
800 mm
Temperature limits
0 - 40°C
Relative humidity
non-condensing
Installation location
above sea level
< 1000 m