The most important spares—overview, Gaskets, Keramott – Austroflamm Vogue User Manual
Page 8: Other parts, Accessories, Maintenance, Important
![background image](/manuals/734113/8/background.png)
Vogue
6 english
Figure 5: Close the Primary Air
As soon as the wood logs are burning well, you
can regulate the heating capacity with the
secondary air slider. (Slider set to the maximum
(“AUF”) setting produces maximum heat – see
Figure 2.)
When adding wood to the fire, follow the same
procedure as when igniting the fire: Open primary
air, open secondary air, carefully open firebox
door, lay wood on the fire, close the firebox door.
Wait until the added wood catches fire and is
burning. Then close the primary air. Subsequently
regulate the fire with the secondary air supply.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description
Nr. drawing Part number
Flat gasket 8 x 2 mm
20/24
710096
Round hollow round gasket 6 mm
22
718183
Round glas fibre gasket 14 mm
23
714223
Keramott
Description
Nr. drawing Part number
Bottom left, keramott
1
712502
Bottom right, keramott
2
712503
Grate 3
716408
Rear, keramott
4
712498
Side component left, keramott
5
712496
Side component left front, keramott
6
712497
Side component right, kermott
7
712499
Baffle plate rear, keramott
8
712505
Baffle plate front, keramott
9
712504
Side component right front, keramott
10
712500
Wood retainer, keramott
11
712501
Other parts
Description
Nr. drawing Part number
Vogue door glass
21
712407
Stove lacquer
--
650002
Stove lacquer aluminium
--
650003
Wood/coal igniter
--
640067
Glass cleaner ½ litre
--
640070
Accessories
You can obtain floor plates of glass or steel, fireplace utensils, care products or the Heat Memory System
for heat storage from your certified dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer. This will guarantee that your
stove functions properly and safely.
Maintenance
To clean the glass, please use a specialized product such as Thermohit glass cleaner. Lacquered
surfaces are to be cleaned only with a cloth (may be damp). Special cleaning agents should also be used
for stainless steel surfaces.
Keramott numbering = installation instructions!