The most important spares—overview, Heating in-between seasons, Chimney fire – Austroflamm Tower Xtra 2.0 User Manual
Page 9: Gaskets, Keramott, Other parts, Accessories, Important, Maintenance, Cleaning

english
7
Tower Xtra 2.0
Heating in-between seasons
Heating the stove in between seasons, when the
outside temperatures are higher, the flue gases may
not be able to escape completely and this may lead to
disturbances in the chimney draught, especially if the
temperatures are rising suddenly. The stove has to
be charged with less wood and the primary air has to
be increased so that the wood can burn down faster
(with visible flames) and thus the chimney flue can
stabilize.
Chimney fire
A chimney fire may occur, due to sooting and
deposits in the chimney, if wrong or humid fuel is
used. Close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have an
expert inspect your chimney for cracks and air-
tightness after the burning out of the chimney.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description Nr.drawing Part
number
Flat gasket 8x2 mm (1,8 m)
13
710096
Gasket round Ø 6 mm (2 x 0,5 m)
14
710696
Gasket round Ø 14 mm (1,8 m)
15
718429
Keramott
Description Nr.drawing Part
number
Bottom left, Keramott
1
714930
Bottom right, Keramott
2
714931
Wood retainer, Keramott
3
714932
Rear, Keramott
4
714933
Side component left, Keramott
5
714934
Side component right, Keramott
6
714935
Baffle plate, Keramott
7
714336
Grate 8
716408
Other parts
Description Nr.drawing Part
number
Door - cast grey
9
718883-29
Door- nougat
9
718883-43
Door handle
10
714661
BA1 door spring
11
718837
Door glass
12
716801
Glass cleaner ½ litre
--
640070
Stove lacquer - cast grey
--
650002
Stove lacquer - nougat
--
650005
Accessories
You can obtain floor plates of glass or steel and care products from your certified dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer. This will guarantee that your
stove functions properly and safely.
The fireplae must not be amended.
Maintenance
To clean the glass, please use a specialized product such as Thermohit glass cleaner. Lacquered
surfaces are to be cleaned only with a cloth (may be damp). Special cleaning agents should also be used
for stainless steel surfaces.
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if
necessary more often, e.g. after the cleaning of the chimney. The chimney also has to be cleaned
regularly by the chimneysweeper. Your chimneysweeper will inform you of the necessary inspection
intervals. An expert should inspect the stove annually.
Keramott numbering = installation instructions!