Dixon 503 User Manual
Page 24
ELECTRICAL SYSTEM:
SITUATION
Starter will not turn
engine over
Starter will not turn
engine over
Battery discharge
Battery discharge
Battery discharge
Electric clutch will
not engage mower deck
blades
Head lights do not
operate
CAUSE
Blown fuse
Dead battery
Poor connections on
battery
Battery water low
Wrong battery Installed 1n
mower
Engine electrical system
not functioning correctly
Engine being operated at
too low an RPM
Low battery condition
Poor connections on clutch
switch
Broken wiring
Poor connection on lights
Broken wiring Bad bulb
REMEDY
Inspect and replace fuse
If fuse continues to
burn consult your
dealer for repair
Charge battery
Tighten or replace as
required
Have electrical
system checked by
your dealer
Increase engine RPM
Consult your dealer
for information
Repair or replace as
required
Consult your dealer
for repair
Repair or replace as
required
Note:
Electrical system failures are generally simple 1n nature, always check the
obvious first and then move onto the more complicated parts used. Poor battery
service, loose connections, corrosion, frayed or broken wiring, are more likely
than component failure.
Page 23
TROUBLE SHOOTING