41

CARE AND MAINTENANCE

HYDROSTATIC TRANSMISSION OIL & FILTER SERVICE

(continued):

5.

Depress by-pass valve on both hydros.

6.

Start engine and move throttle to

mid-range setting.

7.

Release parking brake.

8.

Dirty oil, filled with air bubbles, will

start to drain from oil return hoses

into container. When oil flowing from

hoses is clear and contains no

bubbles, stop the engine.

9.

Re-attach oil return hoses to top of

reservoir.

10. Release by-pass valve on both hydros.

11. Add sufficient oil to reservoir to

return oil level to full mark.