Technical service, Specifications, Warning – Desa VP5A User Manual
Page 20

20
If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
OBSERVED
PROBLEM
Gas odor even when
control knob is in OFF
position
Gas odor during com-
bustion
REMEDY
1. Locate and correct all
leaks (see CHECK-
ING GAS CONNEC-
TIONS, page 10)
2. Replace control valve
1. Take apart gas tubing
and remove foreign mat-
ter
2. Locate and correct all
leaks (see CHECKING
GAS CONNECTIONS,
page 10)
POSSIBLE
CAUSE
1. Gas leak.
See Warn-
ing statement at
top of page
2. Control valve defective
1. Foreign matter between
control valve and
burner
2. Gas leak.
See Warn-
ing statement at
top of page
SPECIFICATIONS
VP11
VP5A
B.T.U. (Variable)
5,500/11,000
5,500
Type Gas
Propane Only
Propane Only
Ignition
Piezo
Piezo
Pressure Regulator Setting
8" W.C.
8" W.C.
Inlet Gas Pressure (inches of water)
Maximum
14"
14"
Minimum
11"
11''
Dimensions, Inches (H x W x D)
Heater
20 1/2 x 13 1/2 x 5
20 1/2 x 13 1/2 x 5
Carton
25 x 16 11/16 x 7 1/2
25 x 16 11/16 x 7 1/2
Weight (pounds)
Heater
14
13
Shipping
17
16
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.
TECHNICAL
SERVICE
!
WARNING ICON
G 001
WARNING